Evidence map›Paper›PMID 41775374›Full record

ArticleJournal of clinical neurology (Seoul, Korea)2026

Comparing Susceptibility-Weighted Imaging and T2* Gradient-Recalled Echo for Cerebral Microbleeds Detection: A Systematic Review and Meta-Analysis.

Su Jeong Yang, Jae-Sung Lim, Yangsean Choi, Ho Sung Kim, Sang Joon Kim, Jae-Hong Lee, Chong Hyun Suh

Abstract read
In one paragraph

Article in Journal of clinical neurology (Seoul, Korea), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Su Jeong YangDepartment of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon, Korea.ORCID https://orcid.org/0000-0002-5707-708X
Jae-Sung LimDepartment of Neurology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-6157-2908
Yangsean ChoiDepartment of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0003-1674-7101
Ho Sung KimDepartment of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-9477-7421
Sang Joon KimDepartment of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-7070-7333
Jae-Hong LeeDepartment of Neurology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-7368-4560
Chong Hyun SuhDepartment of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. chonghyunsuh@amc.seoul.kr.ORCID https://orcid.org/0000-0002-4737-0530

Funding

Asan Institute for Life Sciences, Asan Medical Center 2025IT0007
6 · The paper itself

Abstract

background and purposeCriteria for amyloid-related imaging abnormalities in anti-amyloid therapy are based on T2* gradient-recalled echo (GRE), but susceptibility-weighted imaging (SWI) is widely used, creating uncertainty. This study quantitatively compared the detectability of SWI and GRE for cerebral microbleeds and established evidence supporting distinct microbleed criteria for each.

methodsA systematic review and meta-analysis were conducted following PRISMA guidelines. PubMed and Embase were searched for studies directly comparing SWI and GRE up to August 8, 2024. Study quality was assessed with QUADAS-2. The pooled proportion of microbleed detection and detection ratio were calculated. Subgroup analyses were performed based on magnetic field strength (1.5 T vs. 3 T) and SWI slice thickness (<2 mm vs. ≥2 mm), equipment vendor, and study quality.

resultsThirteen studies were included. SWI detected cerebral microbleeds approximately 1.6 times more effectively than GRE. At 3.0 T and 1.5 T, SWI exhibited 1.7-fold and 1.5-fold greater detectability, respectively. SWI with thinner slices (<2 mm) showed a 1.9-fold improvement, while thicker slices (≥2 mm) showed a 1.3-fold improvement. Subgroup analyses revealed no significant differences between vendors (0.61 vs. 0.60,

conclusionsSWI detects cerebral microbleeds about 1.6 times more effectively than GRE, highlighting important differences between the two techniques. Cautious exploration of adjusted thresholds may be needed, and prospective validation in therapy-specific cohorts will be essential before clinical application.

Indexed as

amyloid-related imaging abnormalitiesanti-amyloid therapycerebral microbleedsusceptibility-weighted imagingT2* gradient-recalled echo

Identifiers

PMID41775374
PMCPMC12956455

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.