Evidence map›Paper›PMID 41770825›Full record

ArticlePloS one2026

Optimal design and operation of Photovoltage distributed generators and shunt compensators for the Vietnam alternative current distribution network to reduce annual energy loss.

Minh Phuc Duong, Bon Nhan Nguyen, Valeriy Arkhincheev, Thang Trung Nguyen

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Minh Phuc DuongPower System Optimization Research Group, Faculty of Electrical and Electronics Engineering, Ton Duc Thang University, Ho Chi Minh City, Vietnam.ORCID https://orcid.org/0000-0003-3949-8603
Bon Nhan NguyenFaculty of Electrical and Electronics Engineering, Ho Chi Minh City University of Technology and Engineering, Ho Chi Minh City, Vietnam.ORCID https://orcid.org/0000-0001-9007-5302
Valeriy ArkhincheevBuryat Institute of Infocommunications, Siberian State University of Telecommunications and Information Science, Novosibirsk, Russia.
Thang Trung NguyenPower System Optimization Research Group, Faculty of Electrical and Electronics Engineering, Ton Duc Thang University, Ho Chi Minh City, Vietnam.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study presents the application of two novel meta-heuristic algorithms, including the Fungal Growth Optimizer (FGO) and Animated Oat Optimization Algorithm (AOO), to optimize the placement of DGs and SCBs for power loss reduction in three alternative current distribution networks (ACDNs), including a practical ACDN with 55 nodes in Vietnam, besides the two IEEE standard ACDNs. In the study, placement of DGs and SCBs on the three grids is conducted in two phases, including the designing phase and the operational phase. In the designing phase, DGs and SCBs were optimized in their placement on the grids by the two algorithms in various scenarios with different DG configurations. The results achieved through scenarios indicate that AOO completely outperforms FGO in terms of the optimal total active power loss values (TAPL) and the stability of the outputs. Particularly, in the two scenarios conducted on the IEEE 69-node, the TAPL achieved by AOO is better than FGO, 3.65% for the first scenario and 72.28% for the second scenario. In the other two scenarios conducted on the IEEE 85-node, AOO still proves its high effectiveness over FGO by reaching the better TAPL at 6.02% in Scenario 1 and 44.88% in Scenario 2. Lastly, AOO is continuously superior to FGO in the four scenarios in the Vietnam ACDN, with 55-node by 1.04% in Scenario 1, 19.52% in Scenario 2, 7.07% in Scenario 3, and 69.60% in Scenario 4. Next in the operational phase, AOO is reapplied to optimize the power output of PVDGs and SCBs within an average day of the first month in the four quarters of the year, with load demand variation and dynamic supplied power from PVDGs in four scenarios with different settings of PVDGs and SCBs. The results clearly reveal that the operational Scenario 4 with PVDGs is configured to supply both active and reactive power to the grid, along with SCBs, which offer the best value of energy loss in the three quarters, except for the third one, where the operational Scenario 2 is the most suited for energy loss.

Indexed as

Electric Power SuppliesSolar EnergyAlgorithmsModels, TheoreticalVietnam

Identifiers

PMID41770825
PMCPMC12952659

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.