ArticleUrolithiasis2026
Comparative evaluation of temperature generation during laser lithotripsy: thulium fiber laser, pulsed thulium: YAG, and holmium: YAG with pulse modulation in an ex vivo porcine kidney model.
Article in Urolithiasis, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Interpreting thermal safety in comparative laser lithotripsy studies.Urolithiasis · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Ureteroscopic laser lithotripsy results in heat generation, raising concern for thermal injury. As laser platforms evolve, comparative assessment of their thermal profiles is increasingly important. This study presents the first comparative evaluation of temperature generation using three contemporary systems: pulsed thulium: YAG (Tm: YAG; Dornier Thulio), thulium fiber laser (TFL; Olympus SOLTIVE), holmium: YAG with pulse modulation (MOSES 2.0; Boston Scientific MOSES 2.0) using manufacturer-recommended dusting settings in an ex vivo porcine kidney model. Eighteen porcine kidney–ureter units were implanted with renal pelvic temperature probes and Bego stones. Specimens were randomized to one of three lithotripsy systems (n = 6 per group; one MOSES specimen excluded). A flexible ureteroscope was introduced via a 35 cm 10/12Fr ureteral access sheath, followed by 10 min of near-continuous dusting using 200 μm fibers (0.3 J/50Hz for TFL and Tm: YAG; 0.3 J/60 Hz for MOSES 2.0). Pressurized irrigation was maintained at 100-150mmHg. Outcomes included absolute temperature change, total energy delivered, and temperature increase normalized to energy (°C/kJ). The greatest mean temperature rise was observed with TFL (8.13 ± 1.96 °C), followed by pulsed Tm: YAG (4.12 ± 1.26 °C) and MOSES 2.0 (3.32 ± 1.84 °C). TFL demonstrated significantly greater heat generation than Tm: YAG (p = 0.0031) and MOSES 2.0 (p = 0.0010). When temperature was adjusted for energy delivery, TFL (1.09 ± 0.30 °C/kJ) surpassed both Tm: YAG (0.47 ± 0.14 °C/kJ; p = 0.0007) and MOSES 2.0 (0.31 ± 0.18 °C/kJ; p = 0.0001). No specimen exceeded temperatures of 43 °C. In this ex vivo setting, TFL was associated with higher heat generation relative to both pulsed Tm: YAG and MOSES 2.0; however, all systems remained below accepted thermal safety thresholds under the tested conditions (43 °C).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.