Evidence map›Paper›PMID 41767330›Full record

ArticleInternational journal of ophthalmology2026

Comparison of three different instruments for vault measurements after implantable collamer lens implantation.

Bo-Liang Li, Ming-Rui Cheng, Wei-Teng Chang, Ya-Di Lei, Guang-Han Xu, Ming-Wei Li, Zhi-Wei Mao, Xun Chen, Xiao-Ying Wang

Abstract read
In one paragraph

Article in International journal of ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Bo-Liang LiFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Ming-Rui ChengFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Wei-Teng ChangFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Ya-Di LeiFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Guang-Han XuFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Ming-Wei LiFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Zhi-Wei MaoFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Xun ChenFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.
Xiao-Ying WangFudan University Eye Ear Nose and Throat Hospital, Shanghai 200031, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography (Pentacam), anterior segment optical coherence tomography (AS-OCT, CASIA II), and ultrasound biomicroscopy (UBM) following implantable collamer lens (ICL) V4c implantation.

methodsVault measurements were acquired using three modalities: Pentacam, CASIA II AS-OCT, and UBM. Repeated-measures analysis of variance was used to compare the vault values obtained by the three devices. The correlation and consistency of measurements among the three instruments were assessed using the Pearson correlation coefficient, intraclass correlation coefficient (ICC), and Bland-Altman plots.

resultsThis retrospective study enrolled 210 myopic eyes of 210 patients (158 women and 52 men) who underwent ICL implantation: 108 eyes had a myopic ICL V4c implanted, and 102 eyes had a toric ICL V4c implanted. The mean vault values measured by Pentacam, CASIA II, and UBM were 452.64±204.20 µm, 538.57±203.54 µm, and 560.95±227.54 µm, respectively, with statistically significant differences among the three groups (

conclusionVault values measured by Pentacam are lower than those obtained by CASIA II and UBM, with UBM yielding the highest mean vault values. Measurements from the three instruments are not interchangeable but can serve as mutual references due to their significant correlation and good overall consistency. Pentacam and CASIA II demonstrate the highest consistency in vault measurement. Notably, when the vault value is ≤250 µm, the consistency between Pentacam and the other two instruments decreases significantly.

Indexed as

anterior segment optical coherence tomographyimplantable collamer lensmeasurement consistencyscheimpflug tomographyultrasound biomicroscopyvault measurement

Identifiers

PMID41767330
PMCPMC12945597

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.