Evidence map›Paper›PMID 41766778›Full record

ArticleIEEE journal of translational engineering in health and medicine2026

Automatic Detection of Onset and Offset of Respiratory Electromyographic Activity in Severe COPD Patients on Non-Invasive Mechanical Ventilation.

Abel Torres, Luis Estrada-Petrocelli, Tim Raveling, Marieke L Duiverman

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Abel TorresUniversitat Politècnica de Catalunya-BarcelonaTech (UPC) Barcelona 08034 Spain.ORCID 0000-0003-2678-1303
Luis Estrada-PetrocelliFacultad de Ingeniería, Secretaría Nacional de Ciencia, Tecnología e Innovación (SENACYT) Sistema Nacional de Investigación (SNI)Universidad Latina de Panamá Panama City 0823-00933 Panama.ORCID 0000-0002-4126-4462
Tim RavelingDepartment of Pulmonary Diseases and Home Mechanical VentilationUniversity Medical Center Groningen, University of Groningen Groningen 9713 GZ The Netherlands.
Marieke L DuivermanDepartment of Pulmonary Diseases and Home Mechanical VentilationUniversity Medical Center Groningen, University of Groningen Groningen 9713 GZ The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAccurate detection of inspiratory onset and offset in the diaphragm electromyographic signal (EMGdi) is clinically relevant to assess patient-ventilator interaction in COPD patients undergoing non-invasive ventilation (NIV). Manual annotations are time-consuming and subject to inter-observer variability, highlighting the need for reliable automatic methods.

methodWe developed a fully automatic algorithm to detect EMGdi activity cycles and their onset/offset timing in overnight NIV recordings. Four ECG suppression approaches were combined with root mean square (RMS) and fixed sample entropy (fSE) envelopes, and a novel bias correction strategy based on inspiratory-to-basal signal-to-noise ratio (I2BSNR) was introduced. Performance was compared with double-blind annotations from two independent experts.

resultsIn a cohort of 10 severe COPD patients (9212 annotated cycles), the best configuration (adaptive filtering with fSE exponential envelope) achieved F[Formula: see text], with onset bias -28 ms (SD 270 ms) and offset bias + 120 ms (SD 292 ms). We show that fSE-based envelopes consistently outperform RMS in onset/offset detection, and that I2BSNR-based correction reduces systematic bias to within accepted clinical timing windows.

conclusionsThe proposed method provides accurate and robust onset/offset detection of EMGdi during NIV in COPD patients. This enables reliable quantification of patient-ventilator asynchronies such as ineffective efforts and delayed cycling, offering direct clinical value for optimizing nightly ventilator settings in severe COPD. Clinical and Impact: Reliable detection of patient inspiratory activity offers a practical tool to guide real-time ventilator adjustments and reduce patient-ventilator asynchronies.

Indexed as

ElectromyographyNoninvasive VentilationPulmonary Disease, Chronic ObstructiveSignal Processing, Computer-AssistedAgedAlgorithmsDiaphragmFemaleHumansMaleMiddle AgedPatient-Ventilator AsynchronyChronic obstructive pulmonary disease (COPD)fixed sample entropy (fSE).non-invasive ventilation (NIV)patient-ventilator asynchrony (PVA)surface diaphragm electromyography (EMGdi)

Identifiers

PMID41766778
PMCPMC12947965

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.