Evidence map›Paper›PMID 41763249›Full record

ArticleBone & joint research2026

Biomechanical study of screw-supported prosthesis in acetabular revision.

Qian Wan, Meng Xu, Hao Chen, Haowen Xue, Baoming Yuan, Bin Zhou, Qing Han, Xin Zhao, Jincheng Wang

Abstract read
In one paragraph

Article in Bone & joint research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Qian WanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.ORCID 0000-0001-7730-8001
Meng XuDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.ORCID 0000-0002-5970-7030
Hao ChenDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.ORCID 0000-0001-9444-1664
Haowen XueDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.ORCID 0000-0003-3832-2438
Baoming YuanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Bin ZhouDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.ORCID 0009-0004-3330-5887
Qing HanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.ORCID 0000-0002-1404-1562
Xin ZhaoDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Jincheng WangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.ORCID 0000-0002-5507-4969

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: Acetabular bone defects pose a common challenge in revision total hip arthroplasty (THA). Our team has applied screw-supported prostheses to the revision of severe acetabular defects and achieved good early clinical results. However, in one of our cases, loosening of the screw-cup connection occurred five months after surgery. Therefore, we investigated the mechanical characteristics and weak points of this prosthesis system through finite element analysis (FEA) and mechanical testing, and proposed improvement strategies. Methods: A screw-supported prosthesis used in clinical practice was modelled, and FEA was performed to obtain its displacement and von Mises stress distribution under gait loading. Emphasis was placed on the stresses at the screw-cup connection to analyze the failure mechanism. Mechanical compression tests were subsequently performed on the prosthesis, and the failure mode of the prosthesis verified the results of the FEA. Results: FEA identified the posterior iliac and pubic locking connections as weak points prone to fatigue failure. Mechanical tests confirmed that the locking connection failed under 2,500 to 3,000 N loads. The improved sleeve connection enhanced connection strength and reduced failure risk. Conclusion: The screw-supported prosthesis shows potential for severe acetabular defects, but the screw-cup connection remains a vulnerable site. Enhanced connection designs (e.g. sleeve connection) and bone grafting effectively mitigate failure risk.

Identifiers

PMID41763249
PMCPMC12949685

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.