Evidence map›Paper›PMID 41761474›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2026

Beyond Boundaries: Proposing an Extended Role for Rapid Deployment Valves in Aortic Valve Redo Surgery.

Julia von der Linden, Philipp Schnackenburg, Polyxeni Vlachea, Florian Herrmann, Shekhar Saha, Sergey Belyaev, Gerd Juchem, Sven Peterss, Dominik Joskowiak, Christian Hagl and 1 more

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Julia von der LindenLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.
Philipp SchnackenburgLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.
Polyxeni VlacheaLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.
Florian HerrmannLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.
Shekhar SahaLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.ORCID 0000-0002-9903-3237
Sergey BelyaevLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.
Gerd JuchemLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.
Sven PeterssLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.ORCID 0000-0003-1880-152X
Dominik JoskowiakLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.ORCID 0000-0003-3995-8737
Christian HaglLMU Klinikum Herzchirurgische Klinik und Poliklinik, 81377 Munich, Bavaria, Germany.
Alexey DashkevichDZHK (German Centre for Cardiovascular Research), Berlin, Germany.ORCID 0000-0001-6166-7210

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesRedo surgical aortic valve replacement (rSAVR) poses challenges, particularly in anchoring a new prosthesis within a deteriorated annulus. While rapid deployment (RD) SAVR is not recommended for redo cases, we retrospectively analysed its potential expanded indication. The primary objective was to examine the potential expanded indication of RD rSAVR and the advantages it might confer, particularly in surgeries with prolonged intraoperative times.

methodsBetween January 2014 and March 2022, 37 patients underwent RD rSAVR (Edwards Intuity Elite rapid deployment valve system (Edwards Lifesciences, Irvine, CA)) due to structural valve degeneration, compared with 48 patients undergoing conventional rSAVR (crSAVR) for aortic stenosis. Data were collected retrospectively after gaining patient consent.

resultsNo significant difference in postoperative or intraoperative complications was obtained, no repeat surgery was performed due to valvular complications in either group, and only 1 paravalvular leak was noted in the crSAVR group. A very low new pacemaker rate was observed in both the groups (3% RD rSAVR vs 6% crSAVR). The cardiopulmonary bypass (CPB) and cross-clamping time is significantly lower in the RD rSAVR collective, which is reflected in the pure rSAVR after stratification according to concomitant procedures. On average, a 23 mm valve was selected in both the groups with comparable postoperative mean gradient. The RD group had a higher TIA rate (19% vs 0%, P = .002), though without residual neurological deficits, but no significant differences in postoperative stroke, respiratory complications, or mortality.

conclusionsRD rSAVR appears safe in redo settings, providing excellent haemodynamic results and time efficiency in experienced hands.

Indexed as

Aortic ValveAortic Valve StenosisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationReoperationAgedAged, 80 and overFemaleHumansMalePostoperative ComplicationsProsthesis DesignRetrospective StudiesTime FactorsTreatment Outcomeaortic valve replacementrapid deploymentredo surgery

Identifiers

PMID41761474
PMCPMC13004218

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.