Evidence map›Paper›PMID 41761131›Full record

ArticleBMC infectious diseases2026

Novel rapid diagnostic system for pathogen identification and antimicrobial susceptibility testing: clinical utility in ICU patients with sepsis.

Agata Chalasiewicz, Jakub Śmiechowicz, Patrycja Trzeciak, Ewa Lewczyk, Waldemar Goździk, Barbara Adamik

Abstract readEvaluation Study
In one paragraph

Article in BMC infectious diseases, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Agata ChalasiewiczDepartment of Microbiology, University Clinical Hospital, Borowska St. 213, Wroclaw, 50-556, Poland. agata.chalasiewicz@usk.wroc.pl.
Jakub ŚmiechowiczClinical Department of Anesthesiology and Intensive Therapy, Wroclaw Medical University, Borowska St. 213, Wroclaw, 50-556, Poland.
Patrycja TrzeciakDepartment of Microbiology, University Clinical Hospital, Borowska St. 213, Wroclaw, 50-556, Poland.
Ewa LewczykDepartment of Microbiology, University Clinical Hospital, Borowska St. 213, Wroclaw, 50-556, Poland.
Waldemar GoździkClinical Department of Anesthesiology and Intensive Therapy, Wroclaw Medical University, Borowska St. 213, Wroclaw, 50-556, Poland.
Barbara AdamikClinical Department of Anesthesiology and Intensive Therapy, Wroclaw Medical University, Borowska St. 213, Wroclaw, 50-556, Poland.

Funding

Uniwersytet Medyczny im. Piastów Slaskich we Wroclawiu SUBZ.A170.25.042
6 · The paper itself

Abstract

backgroundThis study aimed to evaluate a molecular diagnostic system for the rapid identification of pathogens and determination of their antimicrobial susceptibility. By comparing its performance with standard microbiological methods, the study assessed whether the new system could shorten the time to optimal antimicrobial therapy and reliably complement, or potentially replace, conventional diagnostics.

methodsA retrospective study was conducted to evaluate the performance of the Accelerate Pheno system (ACC), a platform for rapid microorganism identification (ID) and antimicrobial susceptibility testing (AST), in comparison with standard-of-care (SOC) laboratory methods for positive blood cultures. The study included adult patients diagnosed with sepsis admitted to the Intensive Care Unit (ICU) who had a positive blood culture result.

resultsThe total turnaround time (from ICU blood sample collection to the availability of both ID and AST results) was significantly reduced from approximately 3 days with SOC methods to 29 h with the ACC system (p < 0.001). In 67% of cases clinical decisions regarding antimicrobial therapy were guided by ACC results: de-escalation in 20%, escalation in 37%, and no changed in 43%; in the remaining 33% of cases, decisions were based on SOC results. Pathogen ID using ACC system was successful in 68% of samples, while in 32% of cases no complete result was obtained. Failure to identify pathogens was due to limitations of the detection panel, partial identification in polymicrobial samples, or technical errors of the system. AST comparison between ACC and SOC methods showed full concordance for Gram-positive organisms. Among Gram-negative bacteria, 95% of AST results were concordant, with discrepancies observed in 5% of determinations, including three very major errors, four major errors, and four minor errors.

conclusionsThe evaluated system substantially shortened the time to pathogen identification and susceptibility reporting. Although complete results were not achieved in all clinically relevant cases, the system demonstrated high concordance with standard methods. Despite some limitations, particularly in pathogen coverage and performance in polymicrobial samples, the system proved to be a valuable complementary diagnostic tool. Its implementation can enhance laboratory efficiency and support earlier, targeted antimicrobial therapy in the management of sepsis.

Indexed as

BacteriaMolecular Diagnostic TechniquesSepsisAdultAgedAnti-Bacterial AgentsFemaleHumansIntensive Care UnitsMaleMicrobial Sensitivity TestsMiddle AgedRapid Diagnostic TestsRetrospective StudiesTime FactorsAnti-Bacterial AgentsAccelerate pheno systemBlood cultureInfectious diseasesIntensive careMicrobiological diagnosticsMolecular diagnosticsRapid testing methodsSepsisTherapeutic decision-makingTime-to-result reduction

Identifiers

PMID41761131
PMCPMC13041058

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.