Evidence map›Paper›PMID 41760215›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2026

[Effect of sacrum-stabilized iliac traction on the stress and displacement of sacroiliac joint and iliolumbar ligament].

Shihao Shi, Shuyan Xu, Xuanyu Zhou, Yuting Wang, Chengxun Han, Meicheng Chen, Ji Qi, Haizhou Wang

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shihao ShiThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.
Shuyan XuThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.
Xuanyu ZhouThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.
Yuting WangThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.
Chengxun HanThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.
Meicheng ChenThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.
Ji QiThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.
Haizhou WangThe Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To investigate the biomechanical effects of sacrum-stabilized iliac traction manipulation on stress and displacement responses in the sacroiliac joint (SIJ) and iliolumbar ligament, a three-dimensional finite element model of the lumbar-pelvic complex was developed based on detailed anatomical structure. First, the articular cartilage and iliolumbar ligament were carefully reconstructed according to realistic human anatomy, with special emphasis placed on creating a solid-element representation of the ligament to accurately simulate its mechanical behavior. After model validation, simulations were performed under both physiological and manipulative loading conditions to quantitatively compare the stress, displacement, and range of motion of the SIJ and iliolumbar ligament. The results showed that under manipulative loading, the SIJ exhibited greater articular surface stress (11.057 MPa), displacement (0.209 mm), and range of motion (0.21°) than under physiological loading, although all values remained within the physiological range. The overall displacement of the iliolumbar ligament during manipulation was also found to be twice that of the joint surface. In conclusion, this study demonstrates that the therapeutic mechanism of sacrum-stabilized iliac traction manipulation primarily relies on stretching and releasing soft tissues and adjusting stress distribution between the joint surface and the iliolumbar ligament, rather than on high-amplitude joint thrust. These findings provide biomechanical support for the clinical application of this technique.

Indexed as

IliumLigamentsLigaments, ArticularSacroiliac JointSacrumTractionBiomechanical PhenomenaFinite Element AnalysisHumansLumbar VertebraeRange of Motion, ArticularStress, MechanicalBiomechanicsFinite element analysisIliolumbar ligamentSacroiliac jointSacrum-stabilized iliac traction

Identifiers

PMID41760215
PMCPMC12948545

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.