Evidence map›Paper›PMID 41760206›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2026

[Master manipulator of vascular intervention surgical robot based on haptic feedback].

Guowei Han, Zhijun Sun, Xiongfeng Tang

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Guowei HanState Key Laboratory of Mechanics and Control for Aerospace Strutures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P. R. China.
Zhijun SunState Key Laboratory of Mechanics and Control for Aerospace Strutures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P. R. China.
Xiongfeng TangState Key Laboratory of Mechanics and Control for Aerospace Strutures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The master manipulator is a crucial component in enabling interactive perception between the physician and the guidewire/catheter; however, the lack of real-time haptic feedback increases the difficulty of hand-eye coordination. This paper designed and developed a master manipulator for a vascular interventional surgery robot with haptic feedback to provide the physician with high-accuracy force feedback. Using a two-degree-of-freedom decoupling mechanism combining key transmission and bearings, the master manipulator captured the physician's push-pull and rotational actions accurately and synchronously. The haptic feedback module adopted dual-channel independent control: axial resistance was generated by three springs evenly distributed at 120° and driven by a linear motor, while circumferential resistance was produced directly by a brushed direct current motor. To enhance the fidelity and accuracy of force feedback, inherent friction within the mechanical structure was identified as a critical non-negligible factor. Consequently, a feedforward compensation strategy grounded in the Stribeck friction model was developed and implemented to proactively counteract friction forces. The performance of the axial force module and the circumferential torque module was evaluated, and the displacement acquisition resolutions reached 1 μm and 0.087 9°, respectively. The average error for axial force feedback was 0.11 N, and that for circumferential torque feedback was 0.154 mN·m. The master manipulator was constructed using a combination of custom 3D-printed photosensitive resin parts and machined aluminum alloy, resulting in a lightweight, low-friction structure. It provides an immersive force-interaction experience for the physician, improving operational precision and radiation safety in vascular interventional surgery and enabling coordinated "vision-hand-force perception".

Indexed as

FeedbackHaptic TechnologyRoboticsRobotic Surgical ProceduresVascular Surgical ProceduresEquipment DesignHumansForce feedback accuracyFriction compensationHaptic feedbackMaster manipulatorVascular interventional surgery robot

Identifiers

PMID41760206
PMCPMC12948638

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials