Evidence map›Paper›PMID 41759625›Full record

ArticleIndian pacing and electrophysiology journal

Inappropriate defibrillator discharge despite evident atrial flutter on stored device electrogram having significant RR variability - What is the mechanism?

Amit Varshney, Amira Shaik, Sanjeev S Mukherjee, Debabrata Bera

Abstract readCase Reports
In one paragraph

Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Amit VarshneyDept of Cardiology, RTIICS, Kolkata, India.
Amira ShaikDept of Cardiology, RTIICS, Kolkata, India.
Sanjeev S MukherjeeDept of Cardiology, AIIMS, Kalyani, India.
Debabrata BeraDept of Cardiology, RTIICS, Kolkata, India. Electronic address: debu2000pgi@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It is crucial to analyze device stored electrograms (EGMs) to decipher whether the therapies were appropriate or inappropriate. We report a case of an inappropriate defibrillator therapy delivered during an obvious atrial tachyarrhythmia despite the dual chamber SVT discriminators being appropriately programmed for underlying rhythm abnormality. The therapy was delivered even though the tachycardia clearly satisfied V < A rate branch along with significant RR interval variability. The morphology match was misleading possibly due to malalignment of the peaks. On the other hand, the Abbott algorithm decides stability delta based on 2nd shortest and longest RR interval. This delta was <40 ms in spite of a irregular rhythm. The Atrio-Ventricular Association (AVA) algorithm, a second check-post designed for such situations, also got deceived due to variation of AV intervals. These led to fulfilment of stringent 'ALL' criteria programmed to make a diagnosis of VT and delivered therapy inappropriately.

Indexed as

AICDInappropriate defibrillator shockSVT discrimination

Identifiers

PMID41759625
PMCPMC13069290

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.