Evidence map›Paper›PMID 41755757›Full record

ArticleMedical physics2026

Filling of incomplete sinograms from sparse PET detector configurations using a residual U-Net.

Klara Leffler, Luigi Tommaso Luppino, Samuel Kuttner, Karin Söderkvist, Jan Axelsson

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Klara LefflerDepartment of Mathematics and Mathematical Statistics, Umeå University, Umeå, Sweden.
Luigi Tommaso LuppinoUiT Machine Learning Group, Department of Physics and Technology, UiT The Arctic University of Norway, Tromsø, Norway.
Samuel KuttnerUiT Machine Learning Group, Department of Physics and Technology, UiT The Arctic University of Norway, Tromsø, Norway.
Karin SöderkvistDepartment of Diagnostics and Intervention, Oncology, Umeå University, Umeå, Sweden.
Jan AxelssonDepartment of Diagnostics and Intervention, Radiation Physics, Umeå University, Umeå, Sweden.

Funding

Swedish Research Council 340-2013-5342
6 · The paper itself

Abstract

backgroundLong axial field-of-view PET scanners are becoming increasingly available worldwide for clinical and research nuclear medicine examinations, providing an increased field-of-view and sensitivity compared to traditional PET scanners. However, a significant cost is associated with manufacturing the densely packed photodetectors required for the extended-coverage systems. Despite improved performance allowing ultralow dose or ultrafast scans, the financial barrier remains, limiting clinical utilisation. PURPOSE: To mitigate the cost limitations, alternative sparse system configurations with strategically placed inter-detector gaps have been proposed, allowing an extended field-of-view PET design with detector costs similar to a standard PET system, albeit at the expense of image quality.

methodsTo address the challenges posed by sparse detector configurations, particularly the heavy undersampling of PET measurements, we propose a deep sinogram restoration network to fill in the missing sinogram data. The network, a modified Residual U-Net, is trained end-to-end using standard clinical PET scans from a GE Signa PET/MR. The training involves simulating the removal of 50% of the detectors in chessboard patterns of varying sizes, leading to incomplete sinograms with significant count losses (thus retaining only 25% of all lines of response).

resultsThe model successfully recovers missing counts in incomplete sinograms, with a mean absolute error consistently below two events per pixel for typical injected radioactivity, outperforming 2D interpolation of incomplete sinograms based on mean absolute error and structural similarity in both sinogram and reconstructed image domain. Notably, the predicted sinograms exhibit a smoothing effect, leading to reconstructed images lacking sharpness in finer details. Despite these limitations, the model demonstrates a substantial capacity for compensating for the undersampling caused by the sparse detector configuration.

conclusionsThis proof-of-concept study suggests that sparse detector configurations, combined with deep learning techniques, offer a viable alternative to conventional PET scanner designs. This approach supports the development of cost-effective, total body PET scanners, allowing a significant step forward in medical imaging technology.

Indexed as

Image Processing, Computer-AssistedPositron-Emission Tomographydeep learningsinogram restorationsparse PET

Identifiers

PMID41755757
PMCPMC12947060

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.