ArticleSensors (Basel, Switzerland)2026
From Motion Artifacts to Clinical Insight: Multi-Modal Deep Learning for Robust Arrhythmia Screening in Ambulatory ECG Monitoring.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Motion artifacts corrupt wearable ECG signals and generate false alarms of arrhythmias, limiting the clinical adoption of continuous cardiac monitoring. We present a dual-stream deep learning framework for motion-robust binary arrhythmia classification through multi-modal sensor fusion and multi-SNR training. ResNet-18 processes ECG spectrograms, while CNN-BiLSTM encodes accelerometer motion patterns; attention-gated fusion with gate diversity regularization adaptively weights modalities based on signal reliability. Training in MIT-BIH data augmented at three noise levels (24, 12, 6 dB) enables noise-invariant learning with successful generalization to unseen conditions. The framework achieves 99.5% accuracy under clean signals, gracefully degrading to 88.2% at extreme noise (-6 dB SNR)-a 46% improvement over training with single-SNR. The high gate diversity (σ>0.37) confirms adaptive context-dependent fusion. With a 0.09% false positive rate and real-time processing (238 beats/second), the system provides practical continuous arrhythmia screening, establishing the foundation for hierarchical monitoring systems where binary screening activates detailed multi-class diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.