Evidence map›Paper›PMID 41755037›Full record

ArticleSensors (Basel, Switzerland)2026

Dedicated Observers for Sensors Fault Detection and Diagnosis in Real Time for Bioreactors.

Patricia Meneses-Martínez, Iraiz González-Viveros, Patricio Ordaz, Ricardo Aguilar-López, Pablo Antonio López-Pérez, Juan Luis Mata-Machuca

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Patricia Meneses-MartínezResearch Center on Technology of Information and Systems, Autonomous University of Hidalgo State, Pachuca 42184, Mexico.ORCID 0009-0005-2033-8580
Iraiz González-ViverosResearch Center on Technology of Information and Systems, Autonomous University of Hidalgo State, Pachuca 42184, Mexico.ORCID 0000-0003-3118-9232
Patricio OrdazResearch Center on Technology of Information and Systems, Autonomous University of Hidalgo State, Pachuca 42184, Mexico.ORCID 0000-0002-5055-2183
Ricardo Aguilar-LópezDepartamento de Biotecnología y Bioingeniería, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Unidad Zacatenco, Ciudad de México 07360, Mexico.ORCID 0000-0003-2697-3153
Pablo Antonio López-PérezEscuela Superior de Apan, Universidad Autónoma del Estado de Hidalgo, Carretera Apan Calpulalpan km. 8, Apan 43900, Mexico.ORCID 0000-0001-7534-2142
Juan Luis Mata-MachucaDepartamento de Tecnologías Avanzadas, Unidad Profesional Interdisciplinaria en Ingeniería y Tecnologías Avanzadas (UPIITA), Instituto Politécnico Nacional, Ciudad de México 07340, Mexico.ORCID 0000-0002-8565-9554

Funding

Instituto Politécnico Nacional 20250976
6 · The paper itself

Abstract

Due to the increasing demand for greater safety and ease of scale bioprocessing, fault detection and diagnosis (FDD) is becoming an effective method to avoid breakdowns and disasters. Therefore, this work focuses on developing a dedicated observer-based fault diagnosis for nonlinear systems. To solve this, the FDD scheme is needed to make it perform satisfactorily even in a faulty situation. A case study on bioethanol production is proposed to illustrate and demonstrate the proposed techniques in real time. Single faults and different sensor faults are considered. The effectiveness of the proposed model is proved by comparing its performance obtained by simulation with the experimental data. In order to supervise the change of the possible faulty parameter, robust adaptive full-order observers that focus not only on the state estimation but also on the parameter change are applied to the considered bioreactor. In order to achieve the desired outcome of sensor fault detection, we propose a residual evaluation function, given by the root-mean-square (RMS) value of the residual and a practical threshold for the bioreactor. Experimental results show that sensor faults can be well diagnosed by the proposed observer-based FDD method. The precision, recall rate, and overall accuracy of three diagnostic metrics for abrupt failures were compared. The diagnostic approach was successful, achieving an overall accuracy rate of over 90% for each of the three abrupt failure scenarios in every sensor. Finally, even if the biomass or CO2 sensors fail, the FDD system can reconstruct the substrate and ethanol dynamics that are typically quantified offline in bioprocesses in real time.

Indexed as

abrupt failuresbioreactordiagnostic metricsfault diagnosisstate estimation

Identifiers

PMID41755037
PMCPMC12944711

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.