Abstract readReview
In one paragraph

Review in Diagnostics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Martina NestiCardiologia Interventistica, Fondazione Toscana Gabriele Monasterio, 56126 Pisa, Italy.ORCID 0000-0001-8995-3884
Maria Laura CanaleU.O.C. Cardiologia-UTIC, Ospedale Versilia, Azienda USL Toscana Nord-Ovest, 55041 Lido di Camaiore, Italy.ORCID 0000-0003-0990-6397
Stefano OlivaU.O.S.D. Cardiologia di Interesse Oncologico, IRCCS Istituto Tumori "Giovanni Paolo II", 70124 Bari, Italy.ORCID 0000-0002-3200-2372
Simona GiubilatoU.O.C. UTIC-Cardiologia ed Emodinamica, AOE Cannizzaro, 95126 Catania, Italy.ORCID 0000-0002-1915-585X
Carlo PignalberiU.O.C. Cardiologia Clinica e Riabilitativa, Presidio Ospedaliero San Filippo Neri, ASL Roma 1, 00135 Roma, Italy.
Rossella TroccoliCardiologia Ospedaliera, Azienda Ospedaliero-Universitaria Consorziale Policlinico di Bari, 70124 Bari, Italy.
Antonio Di MonacoU.O.C. Cardiologia, Ospedale Generale Regionale "F. Miulli", Acquaviva delle Fonti, 70021 Bari, Italy.ORCID 0000-0002-1297-2056
Irma BiscegliaServizi Cardiologici Integrati, Dipartimento Cardio-Toraco-Vascolare, Azienda Ospedaliera San Camillo Forlanini, 00152 Roma, Italy.ORCID 0000-0002-0689-0695
Fabio TurazzaIndependent Researcher, 20162 Milan, Italy.
Claudio BilatoU.O.C. Cardiologia, Ospedali dell'Ovest Vicentino, Azienda ULSS 8 Berica, 36100 Vicenza, Italy.ORCID 0000-0003-3474-0579
Furio ColivicchiU.O.C. Cardiologia Clinica e Riabilitativa, Presidio Ospedaliero San Filippo Neri, ASL Roma 1, 00135 Roma, Italy.ORCID 0000-0001-7187-2234
Massimo GrimaldiU.O.C. Cardiologia, Ospedale Generale Regionale "F. Miulli", Acquaviva delle Fonti, 70021 Bari, Italy.ORCID 0000-0002-9347-8884
Fabrizio OlivaCardiologia 1-Emodinamica, Dipartimento Cardiotoracovascolare "A. De Gasperis", ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The increasing coexistence of oncological disease and cardiovascular implantable technology poses complex clinical challenges that require close collaboration among cardiologists, electrophysiologists, radiation oncologists, and medical physicists. A structured, systematic, and multidisciplinary approach is essential for the safe management of cancer patients with a cardiac implantable electronic device (CIED) undergoing radiation therapy. This document reports a consensus statement issued by the Italian Association of Hospital Cardiologists (ANMCO), aiming to provide practical guidance for clinicians involved across the entire care continuum of this high-risk patient population. A comprehensive pre-treatment evaluation is strongly recommended, including detailed assessment of the type of radiotherapy, treatment planning parameters, device characteristics, and patient-specific cardiac conditions, to minimize the risk of CIED malfunction. Particular emphasis is placed on risk stratification before radiation therapy, as well as on the appropriate timing and modality of cardiological assessments during treatment and in the post-therapy follow-up phase. The document offers an overview of oncological electrophysiology and the mechanisms of radiation-induced damage to cardiac devices with the goal of supporting standardized, safe, and effective clinical practice in this evolving field.