Evidence map›Paper›PMID 41749718›Full record

ArticleBioengineering (Basel, Switzerland)2026

X2P-Net: Context-Aware 2D/3D Vertebra Localization.

Rong Tao, Kangqing Ye, Weijun Zhang, Wenyuan Sun, Derong Yu, Donghua Hang, Guoyan Zheng

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rong TaoInstitute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-6843-3668
Kangqing YeInstitute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0009-0003-8159-7389
Weijun ZhangSchool of Medical Technology, Beijing Institute of Technology, Beijing 100081, China.
Wenyuan SunInstitute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-6049-7843
Derong YuInstitute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0009-0008-6273-5754
Donghua HangDepartment of Orthopedics, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China.
Guoyan ZhengInstitute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0003-4173-0379

Funding

National Key R&D Program of China 2023YFB4706300National Natural Science Foundation of China 62471293National Natural Science Foundation of China U20A20199
6 · The paper itself

Abstract

In the context of minimally invasive spine surgery, accurately estimating the 3D coordinates of the vertebrae from intraoperative 2D X-ray images is crucial for aligning preoperative data with the patient's real-time posture. However, existing methods are hindered by the ill-posed nature of 2D-to-3D localization and the distinctive anatomical features of the spinal column, leading to ambiguities and reduced accuracy. In this paper, we introduce X2P-net, a novel prompt-guided and semantic context-enhanced 2D/3D vertebra detection framework. To achieve this, we design a novel Transformer architecture, referred to as BrickFormer, which can automatically extract the refined vertebral foreground context at low computational cost using a dual-attention mechanism. Comprehensive experiments were conducted to validate the proposed approach on two datasets: a large-scale synthetic dataset (BiSpineX) and a sheep spine dataset (SheepSpineX). Results obtained from these experiments demonstrate superior landmark localization performance of the proposed method compared to other state-of-the-art methods. Specifically, on the BiSpineX dataset, X2P-Net achieves percentages of 96.9% and 98.8% at 10 mm and 20 mm thresholds, respectively, a mean position error of 2.99 mm, and an AUC of 0.9923. Similar superior performance was also observed when the proposed method was applied to the SheepSpineX dataset, with percentages of 98.4% and 100.0% at 10 mm and 20 mm thresholds, respectively, a mean position error of 1.08 mm, and an AUC of 0.9972.

Indexed as

attentionspineTransformervertebra detection

Identifiers

PMID41749718
PMCPMC12938846

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.