Evidence map›Paper›PMID 41749336›Full record

ArticleArthroplasty (London, England)2026

The transepicondylar axis or the posterior condylar axis: Which is the best reference for femoral component rotation in robotic-assisted total knee arthroplasty?

Qing-Da Wei, Hao-Ming An, Yun-Hao Tang, Ming-Feng Li, Rui Li, Wei Chai

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Qing-Da Wei *Senior Department of Orthopedics, the Fourth Medical Center, PLA General Hospital, Beijing, 100037, China.
Hao-Ming An *Senior Department of Orthopedics, the Fourth Medical Center, PLA General Hospital, Beijing, 100037, China.
Yun-Hao TangSenior Department of Orthopedics, the Fourth Medical Center, PLA General Hospital, Beijing, 100037, China.
Ming-Feng LiSenior Department of Orthopedics, the Fourth Medical Center, PLA General Hospital, Beijing, 100037, China.
Rui Li *Senior Department of Orthopedics, the Fourth Medical Center, PLA General Hospital, Beijing, 100037, China. Ryanlee301@163.com.
Wei Chai *Senior Department of Orthopedics, the Fourth Medical Center, PLA General Hospital, Beijing, 100037, China. chaiwei301@163.com.

Funding

AI+ Health Collaborative Innovation Cultivation Z221100003522014
6 · The paper itself

Abstract

backgroundFor robotic-assisted total knee arthroplasty (TKA), accurate identification of anatomical landmarks directly affects the displayed value for femoral component rotation. This study aimed to quantify the inter-surgeon consistency of the TEA-reference angle (the angle between the transepicondylar axis and the femoral component axis) and the PCA-reference angle (the angle between the posterior condylar axis and the femoral component axis).

methodsThe anatomical data of 56 patients who underwent robotic-assisted TKA at our institution were analyzed. Two surgeons independently identified the transepicondylar axis (TEA) and posterior condylar axis (PCA) landmarks on the 3D femoral models generated by the MAKO TKA system. The TEA-reference angle was recorded as α with the PCA-reference angle standardized to 0°, and the PCA-reference angle was recorded as β with the TEA-reference angle standardized to 0°. The measured values were α

resultsThe inter-surgeon intraclass correlation coefficient (ICC) for α was 0.761 (95% CI: 0.592-0.860), and that for β was 0.943 (95% CI: 0.902-0.966). The absolute difference between surgeons (∆α) was > 2° in 15/56 (26.8%) patients and ≤ 1° in 24/56 (42.9%) patients. With respect to ∆β, 3/56 (5.4%) patients had a difference > 2°, whereas 45/56 (80.4%) patients had a difference ≤ 1°.

conclusionThe inter-surgeon consistency of the PCA was significantly greater than that of the TEA in robotic-assisted TKA planning. To mitigate the risk of inappropriate femoral component rotation, surgeons should verify landmark positions, particularly in patients with anatomical abnormalities of the distal femur, and consider cross-referencing both axes. Video Abstract.

Indexed as

Femoral component rotationLandmarkRobotic-assisted surgeryTotal knee arthroplasty

Identifiers

PMID41749336
PMCPMC12947464

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.