Evidence map›Paper›PMID 41745521›Full record

ArticleJournal of functional biomaterials2026

Medial Malleolar Fracture Fixation with Stainless Steel, Titanium, Magnesium, and PLGA Screws: A Finite Element Analysis.

Mehmet Melih Asoglu, Volkan Kızılkaya, Ali Levent, Huseyin Kursat Celik, Ozkan Kose, Allan E W Rennie

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mehmet Melih AsogluOrthopedics and Traumatology Clinic, Private Metrolife Hospital, Sanliurfa 63320, Turkey.ORCID 0000-0001-5872-5758
Volkan KızılkayaOrthopedics and Traumatology Clinic, Private Metrolife Hospital, Sanliurfa 63320, Turkey.ORCID 0000-0002-7472-3303
Ali LeventOrthopedics and Traumatology Clinic, Private Metrolife Hospital, Sanliurfa 63320, Turkey.ORCID 0000-0002-3666-1084
Huseyin Kursat CelikDepartment of Agricultural Machinery and Technology Engineering, Akdeniz University, Antalya 07070, Turkey.ORCID 0000-0001-8154-6993
Ozkan KoseDepartment of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Antalya 07100, Turkey.ORCID 0000-0002-7679-9635
Allan E W RennieEngineering Department, Lancaster University, Lancaster LA1 4YW, UK.ORCID 0000-0003-4568-316X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImplant material may influence interfragmentary mechanics in medial malleolar (MM) fracture fixation. This study aimed to compare stainless steel, titanium, magnesium, and PLGA screws under identical conditions using finite element analysis (FEA).

methodsA CT-based ankle model with a unilateral oblique MM fracture (θ = 60° to the medial tibial plafond) was fixed with two parallel M4 × 35 mm screws placed perpendicular to the fracture plane (inter-axial distance 13 mm). Contacts were defined as nonlinear frictional, and each screw was assigned a pretension force of 2.5 N. Static single-leg stance was simulated with physiologic tibia/fibula load sharing. Four scenarios differed only by screw material. Primary outputs were interfragmentary micromotion (maximum sliding and gap). Secondary measures included fracture interface contact/frictional stresses, screw/bone von Mises stress, global construct displacement, and average tibiotalar cartilage contact pressure.

resultsInterfragmentary micromotion increased as screw stiffness decreased. Maximum sliding was 32.2-33.8 µm with stainless steel/titanium, 40.4 µm with magnesium, and 65.0 µm with PLGA; corresponding gaps were 31.2-32.0 µm with stainless steel and titanium, 31.2 µm with magnesium, and 54.1 µm with PLGA, respectively. Interface stresses followed the same pattern: contact pressure (3.18-3.24 MPa for stainless steel/titanium/magnesium vs. 4.29 MPa for PLGA); frictional stress (1.46-1.49 MPa vs. 1.98 MPa). Peak screw von Mises stress was highest in stainless steel (104.1 MPa), then titanium (73.4 MPa), magnesium (47.4 MPa), and PLGA (17.9 MPa). Global axial displacement (0.26-0.27 mm) and average tibiotalar cartilage contact pressure (0.73-0.75 MPa) were essentially unchanged across materials. All conditions remained below commonly cited thresholds for primary bone healing (gap < 100 µm); however, PLGA exhibited a reduced safety margin.

conclusionsUnder identical geometry and loading conditions, titanium and stainless steel yielded the most favorable interfragmentary mechanics for oblique MM fixation; magnesium showed intermediate performane, and PLGA produced substantially greater micromotion and interface stresses. These findings support the use of metallic screws when maximal initial stability is required and suggest that magnesium may be a selective alternative when reducing secondary implant removal is prioritized.

Indexed as

ankle fracturebiodegradable implantsfinite element analysismagnesiummedial malleolusmicromotionPLGAstainless steeltitaniumvon Mises stress

Identifiers

PMID41745521
PMCPMC12942331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.