ArticleBiomimetics (Basel, Switzerland)2026
Study of the Noise Reduction Mechanism of Bionic Circular Arch Structures on the Blades of a High-Volumetric-Airflow Axial Flow Fan.
Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
While bionic sawtooth and wave structures effectively reduce aerodynamic noise on fixed airfoils, their efficacy on rotating fans is often limited. Inspired by the protrusion structures of dragonfly wings and the gentle circular arches of manta rays, this study proposes a novel bionic circular arch structure to suppress aeroacoustic noise in axial flow fans. Numerical simulations were validated against experimental data from a standard fan, showing a sound pressure level (SPL) deviation within 3 dB at the first blade passing frequency (BPF), confirming calculation accuracy. The results indicate that the bionic design reduces the total SPL by approximately 2.5 dB. Notably, in the human-sensitive frequency range of 1000-3000 Hz, noise reduction reaches up to 6.6 dB at the upstream monitoring point. Analysis of Root Mean Square (RMS) fluctuating pressure and Fourier transforms reveals that the bionic structure significantly mitigates noise source intensity at the blade tip. This design effectively reduces pressure disturbances at the first BPF and shrinks the high-intensity disturbance region of the boundary layer compared to the prototype.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.