ArticleJournal of radiation research2026
Time-dependent 53BP1 foci kinetics in X-irradiated human hair follicle dermal papilla cells.
Article in Journal of radiation research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We investigated the feasibility of a biological dosimetry method using human hair follicle dermal papilla cells (HFDPCs). Cultured HFDPCs were X-irradiated at doses of 50-20 000 mGy, and 53BP1 foci were analyzed up to 96 h post-irradiation to assess DNA double-strand break repair kinetics and dose-response relationships. Up to 5 h post-irradiation, 53BP1 foci increased in a significant dose-dependent manner from 50 to 1000 mGy. By 24 h, the foci count at 50 mGy returned to background levels, whereas dose dependence persisted at higher doses. Notably, analysis of the focus size revealed that the proportion of large foci (diameter ≥ 1 μm) significantly increased at doses ≥ 3000 mGy at 24 h. At 96 h post-irradiation, while total focus counts showed limited discrimination, large-foci assessment maintained significant sensitivity for doses as low as 500 mGy). These findings demonstrate that 53BP1 focus counting in HFDPCs allows for dose estimation from 50 mGy at 5 h, while focus size analysis enhances the accuracy for threshold-based estimation of doses ≥ 500 mGy up to 96 h. This study provides foundational data demonstrating the potential of HFDPCs for biological dosimetry and medical triage, warranting further validation using intact hair samples.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.