Evidence map›Paper›PMID 41743244›Full record

ArticleIranian journal of medical sciences2026

Innovating Patent Ductus Arteriosus Closure: Preclinical Evaluation of the First Iranian-Developed Nitinol Occluder in a Sheep Model.

Hamid Amoozgar, Hossein Hosseini, Hamid Mohammadi, Behrooz Fereidoonnezhad, Mehdi Eynbeygui, Jamal Arghavani, Afshin Zare, Nima Mehdizadegan, Mohammad Reza Edraki, Amir Naghshzan and 2 more

Abstract read
In one paragraph

Article in Iranian journal of medical sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Hamid AmoozgarNeonatal Research Center, Department of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Hossein HosseiniStudent Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran.
Hamid MohammadiDepartment of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Behrooz FereidoonnezhadDepartment of Biomechanical Engineering, Delft University of Technology, Delft, 2628 CD, Netherlands.
Mehdi EynbeyguiDepartment of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
Jamal ArghavaniDepartment of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
Afshin ZareDepartment of Surgery, Shiraz University of Medical Sciences, Shiraz, Iran.
Nima MehdizadeganDepartment of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Mohammad Reza EdrakiDepartment of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Amir NaghshzanDepartment of Pediatrics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Elham AbediHematology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
Mohammadhossein Khorraminejad-ShiraziZoonoses Research Center, Jahrom University of Medical Sciences, Jahrom, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patent ductus arteriosus (PDA) is a congenital defect characterized by abnormal blood flow between the aorta and pulmonary artery. Existing closure devices, such as the Amplatzer Duct Occluder (ADO), face challenges with affordability, biocompatibility, and anatomical adaptability. This study evaluates the safety and feasibility of a novel nitinol-based PDA occluder, the first developed sample in Iran, designed to enhance biocompatibility, reduce thrombogenicity, and improve durability. Methods: This preclinical study was conducted in 2024 at the Large Animal Research Laboratory, Shiraz University of Medical Sciences, Shiraz, Iran. The occluder was fabricated from custom-made nitinol wires braided into a 72-wire conical mesh, ensuring flexibility and durability. Deployment was tested in a sheep model via femoral and pulmonary artery access. Post-procedure evaluations included angiography, clinical monitoring, and histopathological analyses to assess tissue integration, thrombogenicity, and biocompatibility. Results: The device was successfully deployed in two target sites with stable positioning and no procedural complications. Angiographic imaging confirmed vessel patency, even in an artery with a size mismatch. The animal exhibited no adverse outcomes, maintaining normal pulses and activity over a three-month follow-up. Post-mortem analysis revealed secure device placement without migration, perforation, or aneurysm. Histopathological findings demonstrated mild inflammation, neointimal formation, and re-endothelialization, with no significant thrombus or granuloma, indicating excellent biocompatibility. Conclusion: This study provides preliminary evidence supporting the feasibility, safety, and biocompatibility of the Iranian-developed PDA occluder. These findings suggest the device may serve as a viable, cost-effective alternative for PDA closure, addressing device shortages and advancing regional medical technology.

Indexed as

AlloysDuctus Arteriosus, PatentSeptal Occluder DeviceAnimalsDisease Models, AnimalFemaleIranSheepAlloysnitinolBiocompatible materialsNitinolPatent ductus arteriosusSheepThrombosis

Identifiers

PMID41743244
PMCPMC12929902

What OpenQuestion holds

Textmetadata
LicenceCC BY-ND
Read underepoch 390

Registered trials

None linked