ArticleCureus2026
Upper Brachial Artery Access Using a 4-French Sheath for Diagnostic Cerebral Angiography Prior to Transradial Neurointerventional Therapy: A Single-Center Retrospective Study.
Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe transradial access (TRA) is often preferred for neurointerventional therapy; however, radial artery occlusion after diagnostic angiography may limit subsequent TRA. To preserve radial access for neurointerventional therapy, this study proposed using the right transbrachial access (TBA) with a 4-French (Fr) sheath as a method for diagnostic angiography. MATERIALS AND
methodsA retrospective analysis was performed on 51 patients who underwent diagnostic cerebral angiography via the right TBA and subsequently received neurointerventional therapy using right-sided TRA between April 2023 and March 2025. In all cases, a 4-Fr short sheath was inserted into the right upper brachial artery for angiography of the ipsilateral forearm and brachial arteries. If anatomical anomalies were noted, additional left-arm angiography was conducted to assess the feasibility of left-sided TRA during future therapy.
resultsThe mean age of the participants was 67.9 years, and 19 were women. Minor and transient events included puncture-site pain (3.9%) and transient forearm numbness (3.9%), and analgesics were used in 5.9% of cases. There was no subcutaneous hematoma or hemorrhagic event requiring intervention. On angiography during neurointerventional treatment, one (2.0%) patient presented with mild stenosis at the brachial puncture site, and no procedure-related issues were observed. No pseudoaneurysm, arteriovenous fistula, or hematoma with swelling was detected.
conclusionsThe use of the TBA strategy with a 4-Fr sheath in preoperative diagnostic angiography preserves radial artery patency while allowing anatomical evaluation. Hence, this method is a relatively safe and feasible option for centers adopting TRA-based neurointervention.
Indexed as