ArticleAAPS PharmSciTech2026
An Affordable and Simple Novel Approach to Obtain the Heat Transfer Coefficient (Kv) for Primary Drying Models Without Product Temperature Sensors.
Article in AAPS PharmSciTech, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this paper a novel method to obtain the heat transfer coefficient Kv value by the gravimetric method without using product temperature sensors is described. The sublimation front temperature is measured manometrically (indirectly by measuring the pressure). The key finding is a method to obtain the Kv value by using a primary drying model with a tailored algorithm. The authors have named it the gravi-manometric method. Kv values at different pressures are presented for two different containers: a freeze-drying stainless-steel cup, and for nested vials. The traditional gravimetric method has been compared against the new gravi-manometric method. Product temperature measurement can be challenging in applications with complex accessibility, as in large batch freeze dryers or when using protective membranes which enclose the product. This novel method is presented as an affordable and simple procedure by which the Kv value is obtained. The gravi-manometric method has the advantage that all the Kv values for a whole batch of vials can be obtained, as it is not limited to a discrete number of product temperature sensors.
Indexed as
Identifiers
41741903What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.