Evidence map›Paper›PMID 41741150›Full record

ArticleJournal of applied clinical medical physics2026

Quantitative evaluation of a deep learning-based noise reduction algorithm in digital radiography using noise power spectrum analysis.

Sho Maruyama, Hiroki Saitou

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Sho MaruyamaDepartment of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Gunma, Japan.ORCID https://orcid.org/0000-0003-0140-5993
Hiroki SaitouDepartment of Medical Radiology, Faculty of Medical Technology, Teikyo University, Itabashi-ku, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecently, deep learning (DL)-based noise reduction (DLNR) has been introduced in clinically used digital radiography (DR) systems, reporting superior performance over conventional algorithms. However, DLNR algorithms often operate as "black boxes" with nonlinear behavior, making it essential to understand the impact of such processing on image quality under different imaging conditions. PURPOSE: This study aimed to quantitatively evaluate the image quality of a commercial DLNR algorithm for DR referred to as intelligent noise reduction (INR). Specifically, we compared its noise reduction performance with that of a conventional rule-based algorithm (conventional noise reduction, Con-NR) using frequency-domain metrics with detailed noise power spectrum (NPS) analysis.

methodsThe NPS was used to assess the spatial-frequency-dependent behavior of both INR and Con-NR across varying dose levels and different objects. In this work, we introduced a supplementary metric-the NPS improvement factor (NPSIF)-to quantify noise suppression across frequency ranges and facilitate direct comparison between methods.

resultsThe DL-based algorithm achieved substantial noise reduction at low-dose settings compared with the conventional method, although its advantages were less pronounced at higher dose levels. The NPSIF effectively captured frequency-specific differences, thereby offering insights into the strengths and limitations of each technique.

conclusionsThe dose-dependent performance of the DL-based algorithm suggests sensitivity to the characteristics of the training data used to develop the DL model. The findings demonstrate distinct differences in the noise suppression behavior between DL-based and conventional methods in DR and underscore the importance of detailed frequency-domain evaluation for understanding advanced image processing. Further research is warranted to integrate noise analysis with diagnostic performance metrics to comprehensively assess clinical utility.

Indexed as

AlgorithmsDeep LearningImage Processing, Computer-AssistedPhantoms, ImagingRadiographic Image EnhancementSignal-To-Noise RatioHumansdeep learning‐based noise reductiondigital radiographydose‐dependent performancefrequency‐dependent assessmentnoise power spectrum

Identifiers

PMID41741150
PMCPMC12935518

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.