Scanning electron microscopy of artificial corneal endothelial keratoplasty implant.

Mayank A Nanavaty, Issac Levy, Paria Akbari, Martin Smith

Abstract read
In one paragraph

Article in Journal of cataract and refractive surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mayank A NanavatyFrom the University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom (Nanavaty, Levy, Akbari); Brighton & Sussex Medical School, University of Sussex, Falmer, Brighton, United Kingdom (Nanavaty); Ophthalmology Department, Rabin Medical Center, Petach Tikva, Israel (Levy); Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel (Levy); School of Applied Sciences, University of Brighton, Brighton, United Kingdom (Smith).ORCID 0000-0003-0667-3700
Paria Akbari
Martin Smith

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo characterize the surface morphology and edge profile of the artificial corneal endothelial device (EndoArt) using environmental scanning electron microscopy (SEM).

settingUniversity of Brighton, Brighton, United Kingdom.

designHigh-resolution environmental SEM study.

methodsEndoArt specimens underwent examination using an environmental scanning electron microscope (EVO LS15) with variable pressure chamber capabilities, enabling artifact-free examination of hydrophilic materials. Images were digitized at 2048 × 1760 dpi resolution with 200 μm scale markers. Both inner (corneal) and outer (aqueous) surfaces were evaluated at magnifications ranging from 395× to 10.46K×, focusing on surface topography and edge profile characteristics.

resultsThe EndoArt device exhibited a dome-shaped configuration measuring 6.5 mm in diameter with uniform 50 μm thickness. Surface analysis revealed exceptionally smooth topographical characteristics on both surfaces with minimal variation. Both inner and outer surfaces demonstrated pristine, uniform appearance without visible manufacturing marks, scratches, or polymeric irregularities. Surface roughness measurements indicated values well below thresholds associated with cellular adhesion or protein deposition. The edge profile demonstrated optimal tapered design balancing stable tissue adhesion with minimal mechanical trauma. Mirror-like surface quality extended consistently across examined areas, superior to conventional hydrophilic acrylic intraocular lenses which typically exhibit surface irregularities and textural defects.

conclusionsThe exceptional surface smoothness and optimized tapered edge profile documented support the device's barrier function mechanism, correlating with clinical outcomes showing 18% to 37% corneal thickness reductions and representing significant advances in artificial endothelial replacement technology with EndoArt.

Indexed as

Artificial OrgansEndothelium, CornealMicroscopy, Electron, ScanningProstheses and ImplantsCorneal TopographyHumansSurface Properties

Identifiers

PMID41739880
PMCPMC13387680

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.