Evidence map›Paper›PMID 41737864›Full record

ArticleInternational journal of particle therapy2026

Universal Fiducial Markers for Multi-Modal Radiotherapy.

Jie Liu, Caroline Bamberger, Naveed Iqbal, Kevin Reynolds, Smit Shah, Xing Li, Peng Wang, Jiajin Fan, Ashish Chawla, Kevin Choe and 2 more

Abstract read
In one paragraph

Article in International journal of particle therapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jie LiuInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Caroline BambergerInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Naveed IqbalInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Kevin ReynoldsMedical Device Manufacturer, IZI Medical Products, Owing Mills, MD, USA.
Smit ShahMedical Device Manufacturer, IZI Medical Products, Owing Mills, MD, USA.
Xing LiInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Peng WangInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Jiajin FanInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Ashish ChawlaInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Kevin ChoeInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Daniel KimInova Schar Cancer Institute, Inova Health System, Fairfax, VA, USA.
Robabeh RahimiUniversity of Maryland School of Medicine, Baltimore, MD, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Integrating multiple radiotherapy modalities, including photon and proton therapy, within a single clinical facility requires universal fiducial markers that perform reliably across all imaging and treatment systems. For computed tomography (CT) and image-guided radiotherapy (IGRT), fiducials should be large enough to ensure visibility without introducing significant image artifacts. In CyberKnife treatments, a fiducial diameter of at least 0.75 mm is necessary to maintain accurate tracking, particularly in the abdominal and pelvic regions. However, fiducials of this size are unsuitable for proton therapy due to the considerable beam perturbation they cause. This study investigates the design and implementation of customized fiducials that balance imaging visibility, tracking reliability, and proton beam perturbation, enabling their use across multiple radiotherapy modalities. Materials/Methods: Customized coil-shaped platinum fiducials with a 0.75 mm diameter and variable coil gaps were developed to reduce the amount of metal in the proton beam path. For image visibility and trackability assessments, both standard fiducials (0.5 and 0.75 mm diameters with nominally zero coil gaps) and customized versions were inserted in an anthropomorphic phantom. Visibility was evaluated using cone-beam CT (CBCT) and kilovoltage (kV) imaging on both photon and proton treatment systems. Trackability was assessed in the CyberKnife system using an anthropomorphic phantom and a respiratory motion platform. Proton beam perturbation was measured using radiochromic films that were placed downstream of the fiducials and irradiated with a broad spread-out Bragg peak (SOBP) field. A triple-channel film dosimetry method was employed for analysis. Results: Customized fiducials with increased coil gaps demonstrated visibility comparable to standard fiducials in IGRT for both photon and proton systems. In the CyberKnife system, these customized fiducials also provided reliable tracking performance under both static conditions and simulated respiratory motion. The film measurements revealed that the customized fiducials with coil gaps larger than 0.5 mm/coil could significantly reduce proton beam perturbation compared to both the standard 0.75 and 0.5 mm diameter fiducials. Conclusions: This study demonstrates the feasibility of redesigning fiducial markers to maintain a large diameter for reliable imaging visibility and trackability while minimizing proton beam perturbation by increasing the coil gap. Adopting a universal fiducial marker design has the potential to streamline clinical workflows and support seamless integration across various radiotherapy modalities.

Indexed as

Fiducial markersImage-guided radiotherapyImage trackingProton beam perturbationProton therapy

Identifiers

PMID41737864
PMCPMC12927308

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.