Evidence map›Paper›PMID 41735998›Full record

ArticleBMC musculoskeletal disorders2026

Comparing cup implantation errors in total hip arthroplasty following rotational acetabular osteotomy: computed tomography-based navigation versus robotic arm-assisted system.

Yohei Matsushita, Hajime Sugiyama, Tetsuo Hayama, Ayano Amagami, Ryuichi Sato, Makoto Sato, Takuya Maeda, Mitsuru Saito

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yohei MatsushitaDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan. h18msmatsushita@gmail.com.
Hajime SugiyamaDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan.
Tetsuo HayamaDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan.
Ayano AmagamiDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan.
Ryuichi SatoDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan.
Makoto SatoDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan.
Takuya MaedaDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan.
Mitsuru SaitoDepartment of Orthopaedic Surgery, Jikei University School of Medicine, 3 Chome-19-18 Nishishinbashi, Minato City, Tokyo 105-0003, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRobotic arm-assisted total hip arthroplasty (THA) has been reported to achieve acetabular cup implantation that more accurately reproduces the preoperative plan than computed tomography (CT)-based navigation. However, whether this superiority applies in technically demanding cases, such as THA following pelvic osteotomy, remains unclear. Therefore, we evaluated the cup-positioning errors in THA performed with these technologies in patients who had previously undergone rotational acetabular osteotomy (RAO).

methodsTwenty-three patients (24 hips) underwent navigated THA between January 2017 and January 2021 (Navigation group), and 22 patients (24 hips) underwent robotic-assisted THA between February 2021 and February 2023 (Mako group). The error between preoperative planning and postoperative results was calculated and compared between the groups. The absolute values of errors in cup orientation (radiographic inclination and anteversion) and position (mediolateral, anteroposterior, and superoinferior axes) were assessed.

resultsAll absolute errors, except for the superoinferior axis in the Navigation group (3.4 ± 3.5 mm), were within 3° or 3 mm, indicating high accuracy. The absolute error in radiographic inclination was significantly lower in the Mako group than in the Navigation group (0.8 ± 0.8° versus 1.9 ± 1.3°; p = 0.005), whereas errors in radiographic anteversion and position did not differ significantly between the groups. No cup-related complications were noted in either group. From baseline to 2 years postoperatively, the Japanese Orthopaedic Association hip score improved significantly in the Navigation group (from 46.0 ± 9.3 to 89.7 ± 5.9) and the Mako group (from 50.0 ± 12.6 to 93.3 ± 5.8) (both p < 0.001), demonstrating satisfactory clinical outcomes.

conclusionsIn technically demanding THA after RAO, CT-based navigation and robotic-assisted systems demonstrated comparable acetabular cup placement errors and satisfactory short-term clinical outcomes. Although robotic-assisted THA was associated with a significantly smaller error in radiographic inclination, overall cup placement errors did not differ significantly between the two technologies.

Indexed as

AcetabulumArthroplasty, Replacement, HipOsteotomyRobotic Surgical ProceduresSurgery, Computer-AssistedTomography, X-Ray ComputedAdultAgedFemaleHip ProsthesisHumansMaleMiddle AgedRetrospective StudiesAcetabular dysplasiaComputed tomography-based navigation surgeryRobotic arm-assisted surgeryRotational acetabular osteotomyTotal hip arthroplasty

Identifiers

PMID41735998
PMCPMC13041505

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.