Evidence map›Paper›PMID 41735959›Full record

ArticleBMC ophthalmology2026

Panoptix versus AT Lisa: comparing stability of two trifocal intraocular lenses with different haptic designs using the iTrace system.

Dilek Yasa, Husna Topcu, Mevlut Celal Ocal, Mehmet Altun, Gonul Karatas Durusoy, Bulent Kose

Abstract readComparative Study
In one paragraph

Article in BMC ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dilek YasaDepartment of Ophthalmology, Istinye University, Istanbul, Türkiye. dilekyasa2@gmail.com.ORCID http://orcid.org/0000-0002-2445-8484
Husna TopcuDepartment of Ophthalmology, Osmangazi Aritmi Hospital, Bursa, Türkiye.ORCID http://orcid.org/0000-0002-2213-6289
Mevlut Celal OcalDepartment of Ophthalmology, Osmangazi Aritmi Hospital, Bursa, Türkiye.ORCID http://orcid.org/0000-0002-1793-2600
Mehmet AltunDepartment of Ophthalmology, Osmangazi Aritmi Hospital, Bursa, Türkiye.ORCID http://orcid.org/0009-0005-5567-7988
Gonul Karatas DurusoyDepartment of Ophthalmology, Osmangazi Aritmi Hospital, Bursa, Türkiye.ORCID http://orcid.org/0000-0001-7768-9430
Bulent KoseDepartment of Ophthalmology, Osmangazi Aritmi Hospital, Bursa, Türkiye.ORCID http://orcid.org/0000-0001-5399-1512

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe objective of this study was to compare the rotational stability of C-haptic PanOptix Toric (Alcon) and plate haptic AT Lisa Toric (Carl Zeiss Meditec) intraocular lenses (IOLs) using the iTrace system.

methodsThis retrospective study involved 40 patients who underwent trifocal toric intraocular lens (IOL) implantation, either with the PanOptix Toric IOL (Group 1) or the AT Lisa Toric IOL (Group 2). Rotational stability was assessed at the 3-month postoperative visit using the iTrace Surgical Workstation (Tracey Technologies Corp., Houston, TX, USA) after pupil dilation.

resultsGroup 1 comprised 20 patients, and Group 2 comprised 20 patients. The groups exhibited comparable preoperative characteristics, including age, sex, preoperative uncorrected and best-corrected distance visual acuity (UDVA and BDVA), spherical and cylindrical powers, axial length (AL), and corneal astigmatism (all p > 0.05). No statistically significant differences were observed between the groups in best-corrected visual acuity (BCVA), spherical, or cylindrical refractive errors at the three-month postoperative assessment (p > 0.05 for each parameter). The rotation angle, as measured by iTrace following pupil dilation, was 9.30 ± 10.84 degrees in Group 1 and 11.45 ± 8.76 degrees in Group 2 (p = 0.495).

conclusionsThe data demonstrate that trifocal toric IOLs with C-haptic and plate-haptic designs have similar rotational stability in individuals with comparable biometric data.

Indexed as

Lenses, IntraocularLens Implantation, IntraocularMultifocal Intraocular LensesPhacoemulsificationPseudophakiaRefraction, OcularAgedFemaleHumansMaleMiddle AgedProsthesis DesignRetrospective StudiesVisual AcuityAT Lisa ToricC-hapticiTrace surgical workstationPanoptix toric IOLPlate haptic

Identifiers

PMID41735959
PMCPMC13088627

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.