Evidence map›Paper›PMID 41735802›Full record

ArticleAnnals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc2026

Comparative Evaluation of Three Transthoracic Echocardiographic Techniques for Cardiac Output and Stroke Volume Assessment Across Hemodynamic States.

Lei Wang, Da-Wei Wang, Rui-Ming Xu, Jian-Zhong Li, Jing Zhang

Abstract readComparative Study
In one paragraph

Article in Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Are Correlation Analyses Sufficient for Cardiac Output Method Comparison?Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lei WangDepartment of Emergency, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Da-Wei WangDepartment of Emergency, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Rui-Ming XuDepartment of Emergency, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Jian-Zhong LiDepartment of Emergency, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Jing ZhangDepartment of Emergency, Beijing Tongren Hospital, Capital Medical University, Beijing, China.ORCID 0009-0004-8483-4009

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study compared the accuracy of three transthoracic echocardiographic (TTE) techniques-fractional shortening (FS), left ventricular outflow tract velocity-time integral (LVOT/VTI), and Simpson's method-for measuring cardiac output (CO) and stroke volume (SV) in hemodynamically unstable patients (systolic pressure < 90 mmHg), using pulse index continuous cardiac output (PiCCO) as the reference.

methodsA retrospective analysis was conducted involving 12 patients admitted to an Emergency Intensive Care Unit between October 2023 and October 2024, who underwent a total of 54 echocardiographic examinations. The median length of hospital stay is 14 days. CO and SV values obtained using the three TTE methods as part of routine assessment were compared with simultaneous PiCCO measurements. The median number of examinations for patients is 4. Statistical analysis was performed using correlation methods.

resultsAll three TTE methods demonstrated the capability to estimate CO and SV. The VTI method showed the highest overall accuracy (CO-VTI vs. CO-PiCCO: r = 0.950, p< 0.001). Under reduced CO conditions, correlations between echocardiographic and PiCCO-derived measurements decreased for all methods; however, the VTI method maintained superior reliability (r = 0.606, p = 0.006). In contrast, the Simpson's method did not accurately reflect CO in this setting (SV-Simpson vs. SV-PiCCO: r = 0.408, p = 0.083). Notably, the performance of the VTI method remained consistent regardless of SV or heart rate variations (SV-VTI vs. SV-PiCCO: overall r = 0.970; with heart rate > 100 bpm, r = 0.946; with heart rate ≤ 100 bpm, r = 0.988).

conclusionThe LVOT/VTI method exhibits the highest accuracy and consistency for measuring SV and CO, making it the preferred non-invasive technique for hemodynamic evaluation in critically ill patients.

Indexed as

Cardiac OutputEchocardiographyHemodynamicsStroke VolumeAgedFemaleHumansMaleMiddle AgedReproducibility of ResultsRetrospective Studiescardiac outputfocused bedside echocardiographypulse index continuous cardiac outputstroke volumetransthoracic echocardiography

Identifiers

PMID41735802
PMCPMC12932115

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.