ArticleScientific reports2026
Pan-cancer frozen section classification using a soft mixture of experts vision transformer under weak supervision.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Intraoperative frozen section analysis is critical for evaluating tumor malignancy, assessing surgical margins, and informing real-time clinical decisions. However, limitations such as inconsistent slide quality, diagnostic variability, and time constraints challenge its reliability in routine workflows. To address these issues, we collected a real-world dataset of 4,667 hematoxylin and eosin-stained whole slide images (WSIs) from intraoperative consultations spanning diverse organ types. A Vision Transformer (ViT)-based model enhanced with a Soft Mixture of Experts (Soft MoE) module was developed to perform binary classification (benign vs. malignant) under weak supervision using only slide-level labels. The proposed model achieved excellent performance on the test set (AUC = 0.957, sensitivity = 0.817, specificity = 0.961), and demonstrated consistent diagnostic utility across common and rare tissue types. Instance-level heatmap visualizations revealed consistent visual alignment with diagnostic tumor regions, supporting model interpretability. Importantly, the model enables local inference on standard clinical hardware (e.g., GPU with 24 GB memory), making it feasible for real-world deployment. These findings suggest that Soft MoE-ViT offers a practical and interpretable solution for AI-assisted intraoperative pathology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.