Evidence map›Paper›PMID 41733853›Full record

ArticlePhysical and engineering sciences in medicine2026

Bridging precision and practice: dual validation of a high-resolution detector array for beam profiling and patient QA in robotic radiosurgery.

Sandeep Singh, Supratik Sen, Abhay Kumar Singh, Dipesh, Manindra Bhushan, Benoy Kumar Singh, Sarthak Tandon, Munish Gairola

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sandeep SinghDivision of Medical Physics, Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, 110085, India. sandeep.singh82a@gmail.com.ORCID http://orcid.org/0000-0003-0542-6185
Supratik SenDepartment of Radiation Oncology, Dr. B. Borooah Cancer Institute, Guwahati, Assam, India.
Abhay Kumar SinghDivision of Medical Physics, Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, 110085, India. singh.abhay15aug@gmail.com.
DipeshDivision of Medical Physics, Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, 110085, India.
Manindra BhushanDivision of Medical Physics, Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, 110085, India. manindra.drp44@gmail.com.
Benoy Kumar SinghDepartment of Physics, GLA University, Mathura, Uttar Pradesh, India.
Sarthak TandonDepartment of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India. drsarthaktandon@yahoo.in.
Munish GairolaDepartment of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India. gairola.munish@rgcirc.org.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study assessed a high-resolution ionisation chamber-based PTW 1600SRS detector array (array) for beam profile analysis and patient-specific quality assurance (PSQA) in CyberKnife (CK) stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). The goal was to determine its suitability for small fields and non-isocentric delivery, which is unique to robotic platforms. Detector performance was examined for dose linearity, reproducibility, beam profiles, output factors, dose-rate dependence, and verification of the Iris collimator field size. Results were benchmarked against diode-based commissioning data. Clinical applicability was tested by retrospectively verifying 20 intracranial SRS and 20 extracranial SBRT plans using gamma analysis with criteria ranging from 3%/3 mm to 1%/1 mm, as well as 4%/1 mm. The detector showed strong dose linearity (R

Indexed as

Quality Assurance, Health CareRadiosurgeryRoboticsRobotic Surgical ProceduresHumansRadiotherapy DosageReproducibility of ResultsCommissioningCyberKnife robotic radiosurgeryPatient-specific quality assurancePTW 1600SRS detector

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.