Evidence map›Paper›PMID 41733751›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Biomechanical comparison of radiopalmar double plating with conventional palmar plating in comminuted distal radius fractures.

Conrad-Friedrich Jäger, Christian Spiegel, Felix Christian Kohler, Heike Kielstein, Ivan Zderic, Boyko Gueorguiev-Rüegg, Gunther Olaf Hofmann, Mark Lenz, Wolfram Weschenfelder

Abstract readComparative Study
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Conrad-Friedrich JägerDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Jena, Germany.
Christian SpiegelDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Jena, Germany.
Felix Christian KohlerDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Jena, Germany.
Heike KielsteinInstitute of Anatomy and Cell biology, University Hospital in Halle, Halle (Saale), Germany.
Ivan ZdericAO Research Institute Davos, Davos, Switzerland.
Boyko Gueorguiev-RüeggAO Research Institute Davos, Davos, Switzerland.
Gunther Olaf HofmannDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Jena, Germany.
Mark LenzDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Jena, Germany.
Wolfram WeschenfelderDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Jena, Germany. wolfram.weschenfelder@med.uni-jena.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study is to analyse the effect of an additional radial buttress plate for palmar plate osteosynthesis in an AO/OTA 2R3 C2.1 fracture model.

methodsNine pairs of freshly frozen radii were analysed for pathology and bone mineral density and divided into two matched groups. One group was treated with a variable-angle palmar locking plate alone, while the second group received an additional radial buttress plate for radiopalmar double plating. An AO/OTA 2R3 C2.1 fracture was created in all specimens. The biomechanical tests were performed according to previously published protocols. Stiffness, axial displacement of the construct, as well as fragment-specific movements and rotations were assessed.

resultsNo implant failure was observed. In the total cohort, stiffness increased (p < 0.01) and axial construct displacement decreased (p < 0.05). The mobility of the ulnar fragment to the shaft during cyclic testing was lower with double plating, both at baseline and endpoint (all p < 0.01). Fragment movements increased over the course of testing and were significant for the radial articular fragment relative to the shaft in the total cohort (p < 0.01). Baseline rotation of the ulnar fragment and endpoint rotation of the radial fragment in relation to the shaft were lower with double plating (all p < 0.05). In both constructs, the rotation of the ulnar fragment relative to the shaft was lower than that of the radial fragment at both timepoints (all p < 0.05).

conclusionBiomechanically, the addition of a radial buttress plate to a standard palmar locking plate did not alter global construct stiffness, but demonstrated advantages in fragment-specific stability in comminuted distal radius fractures.

Indexed as

Bone PlatesFracture Fixation, InternalFractures, ComminutedPalmar PlateRadius FracturesWrist FracturesAgedBiomechanical PhenomenaCadaverFemaleHumansMaleMiddle AgedBiomechanicDistal radius fractureDorsal comminutionLocking plateRadial buttress plate

Identifiers

PMID41733751
PMCPMC12932277

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.