ArticleMikrochimica acta2026
Cu-triggered ratiometric fluorescence sensor based on dual-emission carbon dots for visual monitoring of thiram in food.
Article in Mikrochimica acta, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
A copper and nitrogen co-doped carbon dots (Cu, N-CDs)-based fluorescent sensor is developed for thiram detection. In detail, with increasing thiram concentration the fluorescence intensity of Cu, N-CDs at 405 nm decreases , while that at 495 nm remains largely unchanged. This phenomenon results from the Cu-induced complex formation, which increases the aggregation of Cu, N-CDs and triggers fluorescence resonance energy transfer. Based on these findings, a good linear correlation is observed ranging from 0 to 100 µM (R2 = 0.99489) thiram under the optimized conditions, with a calculated detection limit (LOD) of 38.7 nM. Moreover, a smartphone-integrated optical sensing platform is developed to enable on-site thiram detection, achieving a LOD of 110.8 nM. Furthermore, this platform has been successfully applied to real samples and shows satisfactory relative recoveries for thiram (96.20%-103.40%) with relative standard deviations ranging from 1.47% to 2.54%. Therefore, this novel Cu, N-CDs based platform provides a helpful strategy for detecting thiram residues in the environment.
Indexed as
Identifiers
41733687What OpenQuestion holds
Registered trials