Evidence map›Paper›PMID 41733489›Full record

ArticleJournal of applied clinical medical physics2026

Implementing log file-based patient-specific QA for VMAT plans: A comparative study of MobiusFX and measurement-based approaches.

Thitipong Sawapabmongkon, Pimolpun Changkaew, Chanon Puttanawarut, Puangpen Tangboonduangjit, Suphalak Khachonkham

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Thitipong SawapabmongkonDivision of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.ORCID https://orcid.org/0000-0003-0144-3789
Pimolpun ChangkaewDivision of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Chanon PuttanawarutChakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Samut Prakan, Thailand.
Puangpen TangboonduangjitDivision of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Suphalak KhachonkhamDivision of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.ORCID https://orcid.org/0000-0003-4771-7941

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe current interest in utilizing log file-based patient-specific quality assurance (PSQA) is growing as an alternative to measurement-based approaches for volumetric modulated arc therapy (VMAT) plans. However, implementing log file-based PSQA requires further experience and understanding since there are no guidelines. PURPOSE: This study aimed to evaluate the feasibility of implementing commercial log file-based PSQA (MobiusFX) for pretreatment verification of VMAT plans by comparing its outcomes with measurement-based methods.

methodsThe study was conducted by selecting 40 VMAT plans and these plans were performed for pretreatment verification for both MobiusFX and measurement-based methods, including portal dosimetry, ArcCHECK, and Octavius4D with gamma analysis at criteria 3%/3 mm, 3%/2 mm, and 2%/2 mm. The agreement of gamma passing rate between MobiusFX and measurement-based methods was assessed through scatter plots and percentage agreement score. Additionally, the root mean square (RMS) errors obtained from MobiusFX were investigated in each machine parameter, and examined the correlation between the gamma passing rate and plan complexity metric (MU/Gy) by Spearman's rank correlation coefficient. The statistical control process concept from TG 218 was also applied to establish the action limit (AL) and tolerance limit (TL) for MobiusFX.

resultsThe scatter plots of MobiusFX illustrated a trend similar to the measurement-based methods, with high percentage agreement scores observed at 3%/3 mm and 3%/2 mm criteria. RMS errors were zero for all parameters except multileaf collimator (MLC), and the maximum RMS was 0.06 mm. No correlation was found between the gamma passing rate and the complexity metric in this study. The most appropriate TL and AL for the gamma passing rate with MobiusFX were determined to be 95.38% and 94.75%, respectively, at the 3%/2 mm criterion.

conclusionMobiusFX showed interchangeable gamma passing rates with measurement-based methods at the 3%/3 mm and 3%/2 mm criteria, supporting its use as an alternative for VMAT pretreatment verification. Machine- and system-specific factors should be considered for reliable clinical implementation.

Indexed as

AlgorithmsNeoplasmsQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansOrgans at RiskParticle AcceleratorsRadiotherapy Dosagelog file‐based PSQAMobiusFXpatient‐specific QAVMAT

Identifiers

PMID41733489
PMCPMC12931424

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.