ArticleJSES international2026
High variability in the degree of liner stability ratio among glenoid components of different anatomical total shoulder arthroplasty systems.
Article in JSES international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Anatomic total shoulder arthroplasty (aTSA) is a viable option for select patients with favorable long-term outcomes. However, instability with static decentering and eccentric wear remains a concern. An important factor contributing to the stability of aTSA is the liner-generated stability ratio, constituted by jump-height and radius of curvature. This study aimed to measure jump height and radius of curvature as well as to assess the liner stability ratio (LSR) of various aTSA glenoid components, enabling comparisons of the degree of constraint between implant systems. Methods: Using manufacturer-independent planning software, glenoid component height, jump height, and radius of curvature in the longitudinal and transverse axes were measured across 28 aTSA systems from 14 companies by two independent raters, with transverse measurements taken at the broadest diameter (t1) and at the corresponding midpoint level of the longitudinal axis (t2); data were validated by comparison with manufacturer-provided specifications. LSR were calculated using a previously validated mathematical formula. The inter-rater reliability was determined using the intraclass correlation coefficient. Visual diagrams illustrated the relationship between glenoid component height, jump height, and LSR across glenoid components of various aTSA designs. Results: The mean glenoid component height was 32.8 ± 4.9 mm (range, 22.3-43.8 mm), while the mean jump height and radius of curvature were 5.1 ± 1.5 mm (range, 2.4-9.9 mm) and 29.7 ± 3.6 mm (range, 21.7-38.1 mm) in the longitudinal axis, 2.7 ± 0.7 mm (range, 1.5-5.1 mm) and 29.5 ± 3.9 mm (range, 19.9-38.5 mm) in the transversal axis (t1), and 2.6 ± 0.7 mm (range, 1.3-4.7 mm) and 29.7 ± 3.9 mm (range, 20.1-39.7 mm) for t2, respectively. Calculated LSR ranged from 39% to 115% (68% ± 15%) for the longitudinal axis, 31% to 71% (47% ± 8%) for t1, and from 28% to 65% (45% ± 8%) for t2, across available aTSA systems. Manufacturer-provided specifications from two companies showed high concordance with the obtained measurements. Regarding LSR consistency, only 2 systems were consistent (≤5% variation) in both axes. Slight inconsistencies (>5-10%) appeared in 3 systems longitudinally and 5 transversely, while most showed >10% variation across sizes. Inter-rater reliability demonstrated near-perfect agreement between testers. Conclusion: This study highlights significant variability in the LSR across different glenoid components of aTSA systems, with inconsistencies often even observed within the same system. While the direct clinical impact remains uncertain, the LSR of the glenoid component in aTSA may have an effect on aTSA stability, component wear and loosening attributed to the rocking horse phenomenon. Further research is needed to clarify the biomechanical consequences of LSR variations on aTSA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.