Evidence map›Paper›PMID 41732428›Full record

ArticleJSES international2026

A biomechanical comparison of fibular strut and femoral head allograft for augmented locking plate fixation in three-part proximal humerus fractures.

Stijn R J Mennes, Igor J Shirinskiy, Charmaine E M Kool, Eric D Tutuhatunewa, Ronald L A W Bleys, Tjarco D W Alta, Michel P J van den Bekerom, Laura M Kok

Abstract read
In one paragraph

Article in JSES international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Influence of allograft augmentation on surgical outcomes and complications in proximal humerus fractures: a matched-pair analysis.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Stijn R J MennesShoulder and Elbow Unit, Department of Orthopaedic Surgery, OLVG, Amsterdam, The Netherlands.
Igor J ShirinskiyShoulder and Elbow Unit, Department of Orthopaedic Surgery, OLVG, Amsterdam, The Netherlands.
Charmaine E M KoolDepartment of Orthopaedic Surgery, Tergooi MC, Hilversum, The Netherlands.
Eric D TutuhatunewaShoulder and Elbow Unit, Department of Orthopaedic Surgery, OLVG, Amsterdam, The Netherlands.
Ronald L A W BleysDepartment of Anatomy, University Medical Center Utrecht, Utrecht, The Netherlands.
Tjarco D W AltaDepartment of Orthopaedics and Traumatology, Spaarne Gasthuis, Haarlem/Hoofddorp, The Netherlands.
Michel P J van den BekeromShoulder and Elbow Unit, Department of Orthopaedic Surgery, OLVG, Amsterdam, The Netherlands.
Laura M KokDepartment of Orthopaedic Surgery, Tergooi MC, Hilversum, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: It is not clear whether cortical fibular allografts or cancellous femoral allografts provide similar stability for augmentation of locking plate fixation of proximal humerus fractures. Therefore, this study aimed to assess and compare biomechanical properties of augmented locking plate fixation with 1) a cortical fibular allograft and 2) a cancellous femoral allograft. Methods: Twenty-two fresh frozen humeri were randomly allocated to undergo unstable three-part fracture creation, locking plate fixation, and augmentation with cortical fibular or cancellous femoral allografts. All constructs were tested with cyclic loading (5 N to 532.5 N) for 1000 cycles at 1 Hz. Subsequently, constructs were loaded to 1700 N. Loss of humeral head height (HHH), ultimate failure loads, mode of failure, and stiffness were assessed. Results: Twenty humeri were included in the analysis. No failure occurred during cyclic loading. During load-to-failure testing, four (40.0%) fibula-augmented constructs and six (60.0%) femoral-augmented constructs failed. During cyclic loading, median loss of HHH was 2.00 (interquartile range [IQR], 1.12-3.50) for fibular grafts and 2.75 (IQR, 2.00-3.00) femoral grafts ( Conclusion: There is no significant difference in biomechanical stability between cortical fibular allograft augmentation and cancellous hip allograft augmentation for locking plate fixation in proximal humerus fractures. Both techniques may equally prevent loss of reduction and early screw protrusion. Cancellous femoral allografts may yield advantages considering costs, availability, and future revision surgery with arthroplasty when compared to cortical fibular allografts.

Indexed as

AugmentationCancellousCorticalFemoral headFibulaFixationLocking plateProximal humerus fracture

Identifiers

PMID41732428
PMCPMC12925068

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.