Evidence map›Paper›PMID 41732216›Full record

ArticleClinical and translational radiation oncology2026

Automated MR-only radiotherapy outperforms CT-based radiotherapy and decreases hands-on time for head-and-neck cancer treatment.

Iris Lauwers, Marta Capala, Sandeep Kaushik, László Ruskó, Cristina Cozzini, Eszter Szabó, Ádám Kékesi, Borbála Deák-Karancsi, Jonathan Wyatt, Rachel Pearson and 4 more

Abstract read
In one paragraph

Article in Clinical and translational radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Iris LauwersDepartment of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands (the).
Marta CapalaDepartment of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands (the).
Sandeep KaushikGE HealthCare, Munich, Germany.
László RuskóGE Healthcare Magyarország Kft., Budapest, Hungary.
Cristina CozziniGE HealthCare, Munich, Germany.
Eszter SzabóGE Healthcare Magyarország Kft., Budapest, Hungary.
Ádám KékesiGE Healthcare Magyarország Kft., Budapest, Hungary.
Borbála Deák-KarancsiGE Healthcare Magyarország Kft., Budapest, Hungary.
Jonathan WyattTranslational and Clinical Research Institute, Newcastle University, Newcastle, UK.
Rachel PearsonNorthern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.
Gerda VerduijnDepartment of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands (the).
Florian WiesingerGE HealthCare, Munich, Germany.
Juan Hernandez-TamamesDepartment of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands (the).
Steven PetitDepartment of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, Netherlands (the).

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Cancer incidence is expected to increase in Europe by 18% in eighteen years. To account for the increasing patient numbers, the workload per patient needs to be reduced. One step towards future-proof radiotherapy is automated MR-only radiotherapy as it could eliminate the need for (i) a planning CT and (ii) for manual organ at risk (OAR) delineations. The aim of this study was to evaluate the feasibility of an automated MR-only workflow for head-and-neck radiotherapy. Method: Automated MR-only radiotherapy consisted of a Zero-Echo-Time-based synthetic CT for dose calculations and automated T2w-based OAR delineations. Automated MR-Only RT was compared to the clinical workflow consisting of CT-based dose calculation and CT-based OAR delineations. Both approaches were benchmarked to a gold standard consisting of the planning CT for dose calculations and manual delineations on the T2w MR scan. Dice similarity coefficients (DSC), 95% Hausdorff distances and absolute DVH metrics were compared between the clinical and MR-only workflow using a linear mixed-effect model. A p-value < 0.05 was deemed significant. Results: Seventeen head-and-neck cancer patients were included. The automated MR-only delineations were more accurate compared to the clinical CT delineations (DSC of 0.79 vs. 0.67; 95% Hausdorff distance 4.0 vs 5.8 mm (p-values < 0.001)). The average dose calculation errors of the automated MR only RT were smaller than the clinical workflow (+0.34 Gy vs. -1.39 (p-value < 0.01)). Discussion: The automated MR-only head-and-neck radiotherapy workflow was more accurate than the standard CT based clinical workflow, demonstrating the feasibility of automated MR-only RT to decrease the workload for head-and-neck RT treatment preparation.

Indexed as

Automatic OAR delineationsDose comparisonHead and neckMR-onlySynthetic CTZTE

Identifiers

PMID41732216
PMCPMC12925503

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.