Observational studyBMC nephrology2026
Hemodialysis vascular sound index as a diagnostic tool for vascular access stenosis: a prospective matched observational study.
Observational study in BMC nephrology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Artificial Intelligence and Sensing Technologies for Vascular Access in Hemodialysis: A Narrative Review.Sensors (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundVascular access (VA) monitoring is critical for hemodialysis patients. While vascular ultrasound (US) provides high diagnostic accuracy for VA stenosis, its reliance on equipment and trained operators can limit routine implementation. The Hemodialysis Vascular Sound Index (HVSI), derived from vascular murmur analysis, may provide a simple, objective adjunct for triaging patients who require confirmatory US and/or vascular access interventional treatment (VAIVT).
objectivesThis study evaluated the diagnostic performance of HVSI for detecting VA stenosis and reduced brachial artery flow volume (FV), and examined its association with US-based parameters including resistance index (RI).
methodsThis prospective matched observational study included 202 hemodialysis patients: 101 with clinically significant stenosis requiring VAIVT (study group) and 101 ultrasound-confirmed stable controls (control group). Participants were matched by age, sex, dialysis duration, diabetes status, Kt/V, and blood data using propensity score matching. HVSI was measured using an electronic stethoscope placed over the anastomosis before dialysis. FV and RI were assessed using Doppler US. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analyses, including sensitivity, specificity, and area under the curve (AUC). A small verification cohort (n = 20) was also analyzed to explore the reproducibility of predefined HVSI cutoffs.
resultsHVSI showed significant correlation with FV (R2 = 0.58, p < 0.001) and inverse correlation with RI (R2 = 0.32, p < 0.001). For FV thresholds ≤500, ≤400, and ≤350 mL/min, HVSI showed sensitivities of 86.3–94.4%, specificities of 78.7–82.9%, and AUCs of 0.90–0.94. Diagnostic accuracy tended to be higher in non-bifurcated vessels. In the verification cohort, predefined HVSI cutoffs showed high specificity for FV < 400 mL/min and strong concordance for identifying VAIVT necessity.
conclusionHVSI demonstrated clinically meaningful diagnostic accuracy for reduced FV and VA stenosis in this matched observational cohort. However, because this design compared clinically evident stenosis cases with ultrasound-confirmed stable controls, diagnostic performance may be overestimated relative to consecutive real-world screening populations. Therefore, HVSI should be interpreted not as a replacement for vascular ultrasound, but as a simple screening adjunct to triage patients who require confirmatory ultrasound and/or VAIVT. Further studies in consecutively enrolled cohorts are warranted to validate generalizability and optimize implementation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.