Evidence map›Paper›PMID 41727379›Full record

ArticleACS measurement science au2026

SERS-Based Immunoassay on Ag/ZnO Nanorod Substrates for Detection of CA125 Antigen.

Luis Zamora-Peredo, María Guadalupe Soriano-Rosales, Adriana Baez-Rodríguez, Julián Hernández Torres, Leandro García-González, Marcos Luna Cervantes, Enrique Juárez-Aguilar

Abstract read
In one paragraph

Article in ACS measurement science au, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Luis Zamora-PeredoCentro de Investigación En Micro Y Nanotecnología, Universidad Veracruzana, Av. Adolfo Ruiz Cortines 455 Costa Verde, Boca Del Río 94294, México.ORCID https://orcid.org/0000-0002-8101-4708
María Guadalupe Soriano-RosalesCentro de Investigación En Micro Y Nanotecnología, Universidad Veracruzana, Av. Adolfo Ruiz Cortines 455 Costa Verde, Boca Del Río 94294, México.
Adriana Baez-RodríguezCentro de Investigación En Micro Y Nanotecnología, Universidad Veracruzana, Av. Adolfo Ruiz Cortines 455 Costa Verde, Boca Del Río 94294, México.ORCID https://orcid.org/0000-0002-8004-8965
Julián Hernández TorresCentro de Investigación En Micro Y Nanotecnología, Universidad Veracruzana, Av. Adolfo Ruiz Cortines 455 Costa Verde, Boca Del Río 94294, México.
Leandro García-GonzálezCentro de Investigación En Micro Y Nanotecnología, Universidad Veracruzana, Av. Adolfo Ruiz Cortines 455 Costa Verde, Boca Del Río 94294, México.
Marcos Luna CervantesCentro de Investigación En Micro Y Nanotecnología, Universidad Veracruzana, Av. Adolfo Ruiz Cortines 455 Costa Verde, Boca Del Río 94294, México.
Enrique Juárez-AguilarInstituto de Ciencias de la Salud, Universidad Veracruzana, Av. Dr. Luis Castelazo Ayala s/n Industrial Animas, Xalapa-Enriquez 91190, México.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Several reports have been published on the detection of the carbohydrate antigen 125 (CA125) cancer biomarker, where the immunoassay is completed with a molecule tag that is detected via surface-enhanced Raman scattering (SERS); however, it is still challenging to detect protein biomarkers without a Raman reporter. In this study, a SERS substrate based on zinc oxide nanorods (ZnO NRs) decorated with silver nanoparticles was fabricated, functionalized, and bioconjugated to detect CA125. Functionalization was performed by using an MPA self-assembled monolayer, which was subsequently surface-activated with an EDC/NHS solution. This process was optimized by using Raman measurements to determine the surface protonation of the substrate. The effect of the concentration and incubation time of the CA125 antibodies on the bioconjugation of the substrate were evaluated. SERS detection of CA125 was successfully achieved in a concentration range of 15-1000 U/mL, demonstrating performance comparable to the ELISA approach. A vibration mode at 829 cm

Indexed as

Ag/ZnO nanorodsCA125cancerimmunoassaylabel-freeSERS

Identifiers

PMID41727379
PMCPMC12921610

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.