Evidence map›Paper›PMID 41727007›Full record

ArticlebioRxiv : the preprint server for biology2026

Friend, not Foe: Lowered Tissue Reactivity to Long-Term Polyimide Implants.

Corinne Orlemann, Laura M De Santis, Paul Neering, Christian Boehler, Kirti Sharma, Arno Aarts, Tobias Holzhammer, Rik J J van Daal, Patrick Ruther, Maria Asplund and 2 more

Abstract readPreprint
In one paragraph

Article in bioRxiv : the preprint server for biology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors.

Corinne OrlemannDepartment of Vision and Cognition, Netherlands Institute for Neuroscience, Amsterdam, Netherlands.ORCID 0000-0001-7939-7546
Laura M De SantisDepartment of Vision and Cognition, Netherlands Institute for Neuroscience, Amsterdam, Netherlands.
Paul NeeringDepartment of Vision and Cognition, Netherlands Institute for Neuroscience, Amsterdam, Netherlands.
Christian BoehlerIntelligent Machine-Brain Interfacing Technology (IMBIT), University of Freiburg, Freiburg, Germany.ORCID 0000-0002-7961-7411
Kirti SharmaCenter BrainLinks-BrainTools, University of Freiburg, Freiburg, Germany.
Arno AartsATLAS Neuroengineering BV, Leuven, Belgium.ORCID 0000-0002-9022-4862
Tobias HolzhammerATLAS Neuroengineering BV, Leuven, Belgium.ORCID 0000-0001-6682-5900
Rik J J van DaalATLAS Neuroengineering BV, Leuven, Belgium.ORCID 0000-0001-5230-6165
Patrick RutherCenter BrainLinks-BrainTools, University of Freiburg, Freiburg, Germany.ORCID 0000-0002-7358-003X
Maria AsplundIntelligent Machine-Brain Interfacing Technology (IMBIT), University of Freiburg, Freiburg, Germany.ORCID 0000-0001-8779-7478
Roxana N KooijmansDepartment of Vision and Cognition, Netherlands Institute for Neuroscience, Amsterdam, Netherlands.ORCID 0000-0001-7808-2243
Pieter R RoelfsemaDepartment of Vision and Cognition, Netherlands Institute for Neuroscience, Amsterdam, Netherlands.ORCID 0000-0002-1625-0034

Funding

Longitudinal neuronal and behavioral responses to microstimulation of LGN by ultraflexible electrodesR01EY036094 · NEI · RICE UNIVERSITY · PI Lan Luan, Chong Xie · 2025 to 2026
$1.2M
NEI NIH HHS R01 EY036094
6 · The paper itself

Abstract

One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity, by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, which were either attached to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, with fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weaker influence of the shank cross-section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex-white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.

Indexed as

BiocompatibilityForeign body responseHistologyIntracortical electrodesNeurotechnology