Evidence map›Paper›PMID 41726004›Full record

ArticleAdvances in radiation oncology2026

Impact of Injection Technique on Microsphere Distribution During Transarterial Radioembolization in a Successively Bifurcating In Vitro Model.

Tess J Snoeijink, Jan L van der Hoek, Anne van den Brekel, Gerhard van Wolfswinkel, Marcel J R Janssen, Erik Groot Jebbink, J Frank W Nijsen

Abstract read
In one paragraph

Article in Advances in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tess J SnoeijinkDepartment of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands.
Jan L van der HoekTechMed Centre, Multi-Modality Medical Imaging Group, University of Twente, Enschede, The Netherlands.
Anne van den BrekelDepartment of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands.
Gerhard van WolfswinkelR&D TIO, Quirem Medical B.V.-A Terumo Company, Deventer, The Netherlands.
Marcel J R JanssenDepartment of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands.
Erik Groot JebbinkTechMed Centre, Multi-Modality Medical Imaging Group, University of Twente, Enschede, The Netherlands.
J Frank W NijsenDepartment of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study aimed to experimentally investigate how injection technique affects the distribution of microspheres during transarterial radioembolization in a successively bifurcating in vitro model. Methods and Materials: A symmetrical phantom, bifurcating 3 times into 8 outlets, was incorporated into a flow circuit. A blood-mimicking fluid was pumped through the phantom using a physiological representative waveform. A microcatheter was placed into the lumen of the phantom, and holmium-165 microspheres were administered with a conventional administration device and a newly designed controlled administration device, containing a rotating syringe to keep the microspheres in suspension during administration. Two clinicians performed manual injections to establish clinically relevant injection rates. Then, different injection profiles were tested using syringe pumps: pulsed vs continuous injections (24 mL/min), and reduced continuous injection rates (10 and 5 mL/min). Microspheres were collected at each outlet and their distribution over the 8 outlets was analyzed. Results: Continuous high injection rates led to more homogeneous radial distributions of microspheres over the right side of the phantom (outlet 5-8 received 16.5%-23.1% of the microspheres per outlet) compared with the clinically standard used pulsed injections (outlet 5-8 received 11.3%-40.1% of the microspheres per outlet). In contrast, reduced continuous injection rates led to more selective distributions (outlet 5-8 received 2.5%-68.8% of the microspheres at 10 mL/min and 1.0%-80.0% at 5 mL/min). Conclusions: Injection technique strongly influences the distribution of microspheres. During high continuous injections, more mixing between microspheres and blood-mimicking fluid was observed. This led to more uniform radial microsphere distributions, creating a more predictive setting for transarterial radioembolization.

Identifiers

PMID41726004
PMCPMC12919237

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.