ArticleIEEE transactions on radiation and plasma medical sciences2026
Semi-Monolithic Detectors for TOF-DOI Brain PET: Optimization of Time, Energy, and Positioning Resolutions With Varying Surface Treatments.
Article in IEEE transactions on radiation and plasma medical sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Multi-Input Interaction Positioning and Signal Demultiplexing With Deep Learning in Semi-Monolithic Detectors.IEEE transactions on radiation and plasma medical sciences · 2026Article
- Performance of high-resolution PET detectors consisting of long GAGG slabs with different reflectors.EJNMMI physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Semi-monolithic detectors, a hybrid configuration combining the benefits of pixelated arrays and monolithic blocks, present a compelling and cost-effective solution for positron emission tomography (PET) scanners with both time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. In this work, we evaluate four LYSO-based semi-monolithic arrays with various surface treatments, read out with the PETsys TOFPET2 ASIC, to identify the optimal configuration for a novel brain PET scanner. The chosen array, featuring ESR on all surfaces except for the black-painted lateral pixelated ones, achieved 15.9 ± 0.6 % energy resolution and 253 ± 15 ps detector time resolution (DTR). neural network with multilayer perceptron architectures were used to estimate the annihilation photon impact position, yielding average accuracies of 3.7 ± 1.1 mm and 2.6 ± 0.7 mm (FWHM) along the DOI and monolithic directions, respectively. The comparative analysis of the four arrays also prompted an investigation into light sharing in semi-monolithic detectors, supported by a GATE-based simulation framework which was designed to complement the experimental results and confirm the observed trends in time resolution. By refining the detector design based on semi-monolithic geometry and optimized surface crystal treatment to enhance positioning accuracy, this study contributes to the development of a next-generation brain PET scanner, with competitive performance but at a moderate cost.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.