Evidence map›Paper›PMID 41724725›Full record

ArticleMagnetic resonance in medicine2026

Accelerating MRI With Longitudinally-Informed Latent Posterior Sampling.

Yonatan Urman, Zachary Shah, Ashwin Kumar, Bruno P Soares, Kawin Setsompop

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yonatan UrmanElectrical Engineering, Stanford University, Stanford, California, USA.ORCID 0000-0002-5763-8174
Zachary ShahElectrical Engineering, Stanford University, Stanford, California, USA.ORCID 0009-0006-8652-1924
Ashwin KumarRadiology, Stanford University, Stanford, California, USA.ORCID 0009-0002-9859-4275
Bruno P SoaresRadiology, Stanford University, Stanford, California, USA.ORCID 0000-0003-4185-6940
Kawin SetsompopElectrical Engineering, Stanford University, Stanford, California, USA.ORCID 0000-0003-0455-7634

Funding

Next generation in-vivo diffusion imaging at submillimeter resolutionR01MH116173 · NIMH · STANFORD UNIVERSITY · PI Yogesh Rathi, Kawin Setsompop · 2018 to 2026
$6.2M
fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution: Administrative SupplementR01EB019437 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO, SETSOMPOP, KAWIN · 2015 to 2024
$5.5M
NIH HHS R01EB019437NIH HHS R01MH116173NIMH NIH HHS R01 MH116173
6 · The paper itself

Abstract

purposeTo accelerate MRI acquisition by incorporating the previous scans of a subject during reconstruction. Although longitudinal imaging constitutes much of clinical MRI, leveraging previous scans is challenging due to the complex relationship between scan sessions, potentially involving substantial anatomical or pathological changes, and the lack of open-access data sets with both longitudinal pairs and raw k-space needed for training deep learning-based reconstruction models.

methodsWe propose a diffusion-model-based reconstruction framework that eliminates the need for longitudinally paired training data. During training, we treat all scan timepoints as samples from the same distribution, therefore requiring only standalone images. At inference, our framework integrates a subject's prior scan in magnitude DICOM format, which is readily available in clinical workflows, to guide reconstruction of the follow-up. To support future development, we introduce an open-access clinical data set containing multi-session pairs including prior DICOMs and follow-up k-space.

resultsOur method consistently outperforms both longitudinal and non-longitudinal baseline reconstruction methods across various accelerated Cartesian acquisition strategies. In imaging regions highly similar to the prior scan, we observe up to 10% higher SSIM and 2 dB higher PSNR, without degradation in dissimilar areas. Compared to longitudinal reconstruction baselines, our method demonstrates robustness to varying degrees of anatomical change and misregistration.

conclusionWe demonstrate that prior scans can be effectively integrated with state-of-the-art diffusion-based reconstruction methods to improve image quality and enable greater scan acceleration, without requiring an extensive longitudinally paired training data set.

Indexed as

BrainImage Processing, Computer-AssistedMagnetic Resonance ImagingAlgorithmsDeep LearningHumansImage Interpretation, Computer-AssistedLongitudinal Studiesdeep learninglongitudinal MRIreconstruction

Identifiers

PMID41724725
PMCPMC13049276

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.