Evidence map›Paper›PMID 41722009›Full record

ArticleInternational urology and nephrology2026

Prospective pilot evaluation of a deep learning model for kidney stone detection on CT using a web-based workflow platform.

Coşku Öksüz

Abstract read
PubMed Publisher
In one paragraph

Article in International urology and nephrology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Coşku ÖksüzDepartment of Electrical and Electronics Engineering, Faculty of Engineering and Architecture, Izmir Bakırçay University, İzmir, Turkey. cosku.oksuz@bakircay.edu.tr.ORCID http://orcid.org/0000-0001-7116-2734

Funding

Türkiye Bilimsel ve Teknolojik Araştırma Kurumu 123E442
6 · The paper itself

Abstract

Rapid and reliable detection of kidney stones on non-contrast abdominal CT is essential for timely decision-making in emergency radiology. However, rising imaging volumes and workflow pressures continue to limit reporting capacity, creating a need for AI systems capable of supporting routine diagnostic practice. Although many AI-based stone detection models have been proposed, most rely on retrospective datasets, and few have been evaluated prospectively within environments that reflect real radiology workflow conditions. This study prospectively evaluates the performance, usability, and workflow compatibility of a deep learning-based kidney stone detection model deployed within a web-based platform designed to emulate key components of routine radiology practice, enabling forward-in-time evaluation without direct integration into routine clinical operations such as PACS/RIS or clinical reporting. A dual-stage convolutional neural network was developed using an internal dataset of 235 cases (3,452 slices) and validated through five-fold patient-level cross-validation. An independent set of 732 slices served as an independent hold-out set. For prospective evaluation, the trained model was integrated into a secure, browser-based interface supporting case upload, slice-level review, independent radiologist labeling, and visualization of AI-generated predictions. Over a six-month period, three radiologists uploaded and annotated a total of 5,152 anonymized CT slices. The platform dynamically calculated diagnostic metrics and logged human-AI interactions to assess performance stability and concordance. The pilot deployment demonstrated strong diagnostic performance under real-world variability, achieving 97.83% accuracy, 94.64% sensitivity, 98.27% specificity, 88.50% precision, and a Cohen's kappa of 0.90. Concordance between radiologists and the model exhibited increasing stability across sequential pilot stages. These findings present a reproducible framework for transitioning radiological AI systems from retrospective validation toward workflow-aligned, prospective pilot deployment. Although full PACS/RIS integration was not attempted, the results underscore the importance of pilot-stage evaluation as a critical intermediary step toward clinical implementation and regulatory approval.

Indexed as

Deep LearningInternetKidney CalculiTomography, X-Ray ComputedWorkflowConvolutional Neural NetworksHumansPilot ProjectsProspective StudiesClinical decision supportClinical workflow integrationDeep learningKidney stone detectionNon-contrast CTProspective pilot studyUrolithiasis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.