ArticleCVIR endovascular2026
Coil-out: comparing outcomes after prostate artery embolization with and without endovascular coiling.
Article in CVIR endovascular, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This retrospective study evaluates post-procedural symptom score changes after prostate artery embolization (PAE) with (Coil-out) and without (Standard) adjunctive prostate artery coiling after particle embolization. Changes in IPSS, QOL/Bother, and SHIM-IIEF V are reported at 1-5- and 9-15-month intervals. 573 procedures were reviewed, and 317 patients were included with a mean age of 72.1 years. Results favored the Standard group with greater IPSS reduction at 1-5 (-12.2 vs. -9.9, p = 0.018) and 9-15 months (-12.5 vs. -7.6, p = 0.018), and greater QOL/Bother improvement in the Standard group at 9-15 months (-2.8 vs. -1.8, p = 0.014). Procedure times were longer in the Standard group (186 vs. 173 min; p = 0.039), whereas fluoroscopy times were longer in the Coil-out group (48.3 vs. 44.8 min; p = 0.014). Though limited by retrospective nature and lack of longer-term follow-up, these results support particle embolization alone over adjunctive coil embolization for PAE.
Identifiers
What OpenQuestion holds
Registered trials