Evidence map›Paper›PMID 41718466›Full record

ArticleEpilepsia open2026

Safety of postimplantation MRI with Dixi microdeep electrodes in situ: An in vitro evaluation of MRI-related heating at 1.5T.

Ruth O'Gorman Tuura, Roger Luechinger, Rahel Heule, Raimund Kottke, Sabine Rona, Niklaus Krayenbühl, Georgia Ramantani

Abstract read
In one paragraph

Article in Epilepsia open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ruth O'Gorman TuuraCenter for MR Research, University Children's Hospital, Zurich, Switzerland.ORCID https://orcid.org/0000-0001-5932-7786
Roger LuechingerInstitute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-7365-0421
Rahel HeuleCenter for MR Research, University Children's Hospital, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-4589-6483
Raimund KottkeChildren's Research Center, University Children's Hospital, Zurich, Switzerland.ORCID https://orcid.org/0000-0003-0166-2770
Sabine RonaSwiss Epilepsy Center, Klinik Lengg, Zurich, Switzerland.
Niklaus KrayenbühlChildren's Research Center, University Children's Hospital, Zurich, Switzerland.ORCID https://orcid.org/0000-0003-1089-221X
Georgia RamantaniChildren's Research Center, University Children's Hospital, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-7931-2327

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivePostimplantation assessment of the position of depth EEG electrodes for intracerebral recordings in patients with refractory focal epilepsy can be performed with MRI or with CT after coregistration to a preimplantation MRI. While both methods offer risks and advantages, postimplantation MRI risks depend on the electrode heating profile under different MRI conditions. We aimed to assess the MRI-related heating of Dixi microdeep electrodes at 1.5T in multiple electrode configurations and with varying levels of radiofrequency (RF) power.

methodsIn vitro tests of heating due to RF power deposition were performed according to the F2182-19e2 standard from the ASTM (American Society for Testing and Materials International). A 10-contact Dixi microdeep electrode was inserted into the gel within the ASTM head-torso phantom, and the temperature was recorded from selected electrode contacts during MRI. Tests were performed with the electrode positioned in various locations in straight and coiled configurations, with coil diameters from 6 to 25 cm. MRI was conducted on a 1.5T Philips Achieva scanner using the transmit-receive body coil.

resultsSignificant heating was observed for all configurations where more than 12 cm of the electrode was in the RF coil, apart from those with an applied specific absorption rate (SAR) ≤0.16 W/kg and with additional coiling of the electrode lead using a diameter of ≤6 cm. The worst-case configurations, reaching a maximum temperature of 70°C (temperature rise 48°C), occurred where the electrode end was straight or looped with a large-diameter (25 cm) loop. Heating was greatest in the contact furthest from the tip. SIGNIFICANCE: Dixi microdeep electrodes demonstrate heating levels capable of causing serious injury during MRI, but using a conservative SAR limit of 0.1 W/kg and coiling the electrode lead to a diameter of ≤6 cm appears to reduce the heating risk. PLAIN LANGUAGE SUMMARY: Electrodes positioned within the brain for planning epilepsy surgery can heat up during MRI. Using a standard test object mimicking the electrical properties of the human body, we measured heating of Dixi microdeep depth electrodes in different positions and orientations and with varying levels of radiofrequency power. We found substantial heating apart from when the radiofrequency power was greatly restricted or when the lead was tightly coiled. Different electrode contacts showed drastically different heating, and heating levels capable of causing serious injury were measured during MRI.

Indexed as

Electrodes, ImplantedHot TemperatureMagnetic Resonance ImagingBrainElectrodesElectroencephalographyHumansPhantoms, ImagingepilepsyicEEGMRI safetyRF heatingSARstereoencephalography

Identifiers

PMID41718466
PMCPMC13051839

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.