Evidence map›Paper›PMID 41716972›Full record

ArticleGMS hygiene and infection control2026

How to get cheap clean air? Implementation of an affordable high-efficient air filtration ventilation system for operating theatres in a low-resource setting.

Christian Leonhard Doll, Rolf Opalka, Leonel Tchamo Nguifo, Alaric Tamuedjoun Talom, Lazare Kuate Kamdem, Alexandra Will, Lilith Johannsen, Florian Geiger, Andrej Trampuz

Registry-linked trialAbstract read
In one paragraph

Article in GMS hygiene and infection control, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07034573 (Evaluation of the Performance of the Ventilation-filtration System for Operating Rooms at the Protestant Hospital of Mbouo-Bandjoun), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07034573 completednot on this map

Evaluation of the Performance of the Ventilation-filtration System for Operating Rooms at the Protestant Hospital of Mbouo-Bandjoun (VENTI-MBOUO)

TypeobservationalSponsorChristian DollRan2024 to 2024Enrolled1ConditionsSurgical Site Infections, InfectionsArmscontext adapted air filtration system for operating theatre
3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Christian Leonhard DollSpine and Scoliosis Center, Hessing Foundation, Augsburg, Germany.
Rolf Opalkacl3an air consulting, Herten, Germany.
Leonel Tchamo NguifoMbouo Protestant Hospital, Mbouo/Bandjoun, Cameroon.
Alaric Tamuedjoun TalomFaculty of Sciences and Technology, Evangelical University Institute of Cameroon, Mbouo/Bafoussam, Cameroon.
Lazare Kuate KamdemMbouo Protestant Hospital, Mbouo/Bandjoun, Cameroon.
Alexandra WillSystemic Centre Augsburg, Augsburg, Germany.
Lilith JohannsenPRO-IMPLANT Foundation, Berlin, Germany.
Florian GeigerSpine and Scoliosis Center, Hessing Foundation, Augsburg, Germany.
Andrej TrampuzPRO-IMPLANT Foundation, Berlin, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: Clean air in the operating theatre (OT) is crucial for safe surgery in order to prevent surgical site infections. Air filtration devices are standard in most OT as required by international guidelines and regulations. However, in low-resource settings, common air filtration devices are only scarcely found in OT, mainly due to high cost. Context-adapted low-cost solutions for clean air in OT are urgently needed but not available. The aim of this study was to assess the effectiveness of a new mechanical air filtration system for OTs, to describe its technical details and compare its performance with DIN/ISO standards and natural window ventilation, at a district hospital in Mbouo, Cameroon. Methods: An affordable (3,500 €) high-efficient air filtration system was developed, locally constructed and implemented. An evaluation was done after 4 years of regular use, comparing the system with ISO/DIN guidelines. Results: The device was still working properly after 4 years of regular use without any maintenance. The air filtration system reduced particles in the OT by >97%. The microbial contamination in the OT air was reduced by 72% after starting the device. Although it is not fully compliant with all DIN/ISO requirements, the ventilation system greatly improved the cleanliness of the OT air compared to 'natural' window-based ventilation. Conclusions: This pilot study showed the feasibility and quality of a new context-adapted affordable air filtration device for OT in low-resource settings. Further studies and upscaling are needed. Construction plans are freely available.

Indexed as

Africaair conditioningCameroonoperating roomssurgical wound infectionventilation

Identifiers

PMID41716972
PMCPMC12914505

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.