Hierarchical deep learning pipeline for robust cervical parameter measurement in radiographs with C7 obscuration.
Article in NPJ digital medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We developed and externally validated a hierarchical deep learning pipeline that automates cervical sagittal measurements, explicitly addressing C7 obscuration on lateral radiographs. The model combines a global keypoint detector with C2/C7 specialists localized via a multilayer perceptron to refine landmarks on high‑resolution patches. Trained on 5604 images and tested internally and on a challenging external cohort enriched for C7 obscuration (82%), it achieved excellent agreement with ground truth. Externally, intraclass correlation coefficients (ICCs) were 0.97 for lordosis (mean absolute error [MAE] 2.6°), >0.99 for C2 slope (MAE 0.8°), and 0.93 for C7 slope (MAE 2.3°), with minimal bias and narrower limits of agreement than a single‑stage baseline. The model showed near-perfect repeatability (ICC > 0.99) and higher artificial intelligence-expert agreement (ICC 0.81-0.84) for C7 slope than inter-expert reliability (ICC 0.67). In failure cases, the pipeline corrected large global model errors (e.g., 10.22°- 0.22°). This robust, coarse‑to‑fine approach advances reliable, generalizable cervical alignment assessment in real‑world conditions.