Evidence map›Paper›PMID 41714447›Full record

ArticleScientific reports2026

Reversible magnetic behavior in amorphous wires for precision sensing applications.

T-A Óvári, M Lostun, S Corodeanu, G Ababei, H Chiriac, N Lupu

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

T-A ÓváriNational Institute of Research and Development for Technical Physics, 15 Mangeron Boulevard, Iași, 700050, Romania.
M LostunNational Institute of Research and Development for Technical Physics, 15 Mangeron Boulevard, Iași, 700050, Romania.
S CorodeanuNational Institute of Research and Development for Technical Physics, 15 Mangeron Boulevard, Iași, 700050, Romania.
G AbabeiNational Institute of Research and Development for Technical Physics, 15 Mangeron Boulevard, Iași, 700050, Romania.
H ChiriacNational Institute of Research and Development for Technical Physics, 15 Mangeron Boulevard, Iași, 700050, Romania.
N LupuNational Institute of Research and Development for Technical Physics, 15 Mangeron Boulevard, Iași, 700050, Romania. nicole@phys-iasi.ro.

Funding

Ministerul Educaţiei şi Cercetării Nucleu Program (Project PN 23 11 01 01)Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii PN-IV-P1-PCE-2023-1896 - Contract no. 12PCE/03.01.2025
6 · The paper itself

Abstract

Amorphous magnetic wires based on Co-Fe alloys exhibit exceptionally soft magnetic behavior, making them attractive for advanced sensing technologies. Their magnetic performance is governed primarily by internal stresses, magnetoelastic interactions, and induced anisotropies. We demonstrate that helical magnetic anisotropy induced by stress annealing is fully reversible upon thermal relaxation, a mechanism not previously demonstrated for resetting the magnetic state in these wires. Magneto-optical Kerr effect imaging reveals corresponding changes in surface domain structures, confirming the reversible nature of magnetization processes at the microscale. We attribute this behavior to anelastic rearrangements and orientational ordering of nanoscale clusters within the amorphous matrix, which modulate magnetoelastic energy and produce the induced anisotropy. The demonstrated reversibility provides a mechanism for resettable or tunable magnetic responses in wire-based magnetic sensors and other precision electromagnetic devices.

Indexed as

Amorphous magnetic wiresMagnetic sensingMagneto-optical Kerr effect (MOKE)MagnetostrictionReversible magnetic anisotropyStress annealing

Identifiers

PMID41714447
PMCPMC13018552

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.