Evidence map›Paper›PMID 41714443›Full record

ArticleAnnals of biomedical engineering2026

Additively Manufactured Partially Porous PAEK Topologies for Proximal Tibia Revision Cones and Sleeves.

Paul M DeSantis, Emma Barnes, Abigail Tetteh, James A Smith, Drew Mike, Corey Perine, Steven M Kurtz

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Paul M DeSantisImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, 19104, USA. pmd67@drexel.edu.ORCID http://orcid.org/0000-0003-1535-6125
Emma BarnesImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, 19104, USA.
Abigail TettehImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, 19104, USA.
James A SmithImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, 19104, USA.
Drew MikeMaxx Orthopedics, Inc., Norristown, PA, 19403, USA.
Corey PerineMaxx Orthopedics, Inc., Norristown, PA, 19403, USA.
Steven M KurtzImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, 19104, USA.

Funding

Pennsylvania Department of Community and Economic Development 1060176-483735
6 · The paper itself

Abstract

Metaphyseal cones and sleeves are an increasingly common component utilized in revision total knee arthroplasty. These partially porous devices have a high surface area and aim to integrate with cancellous bone of the distal femur and proximal tibia to increase the stability of the implant. Incidences of metal-hypersensitivity and macrophage-stimulated osteolysis have motivated the development of a non-metal alternative in the form of   polyaryletherketone (PAEK) implants. We hypothesized that highly complex porous PAEK components could be additively manufactured to withstand the mechanical forces of the knee, while still allowing for bone ingrowth. Taguchi optimization was used to investigate parameters and porous geometries that achieved the highest ultimate load in 45° shear-compression. Micro-CT was used to evaluate the quality of the print porosity for each experimental group. Low-melt (LM) PAEK sample means exceeded all polyetheretherketone (PEEK) means, and geometry and percent porosity were found to be the most significant parameters for LM PAEK, while nozzle temperature, chamber temperature and layer height were the most significant for PEEK (p < 0.05). All samples passed the theoretical worst-case scenario of ~ 5.5 kN ultimate load in 45° shear. The mean errors for percent porosity were not significantly different (p > 0.05) and measured to be - 8.46% and - 12.25% for PEEK and LM PAEK groups, respectively. This work serves as a proof-of-concept for 3D printing highly porous non-metal metaphyseal sleeves/cones without compromising on strength.

Indexed as

Arthroplasty, Replacement, KneeKetonesKnee ProsthesisPolyethylene GlycolsTibiaBenzophenonesHumansPolymersPorosityProsthesis DesignBenzophenonesKetonespolyetheretherketonePolyethylene GlycolsPolymers3D printingAdditive manufacturingMetaphyseal coneMetaphyseal sleevePAEKPEEKPolyaryletherketone

Identifiers

PMID41714443
PMCPMC13290881

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.